The network management connector (NET MGT) is an RJ-45 port and provides an alternate
terminal interface to the SP console.
There are four RJ-45 Gigabit Ethernet ports (NET0, NET1, NET2, NET3) located on the
motherboard that operate at 10/100/1000 Mbit/sec. These network interfaces must be
configured before use.
Electrical Specifications
The following list shows the electrical specifications for the 7120. Note that the power
dissipation numbers listed are the maximum rated power numbers for the power supply. The
numbers are not a rating of the actual power consumption of the appliance.
Connectors
■
Two C13 connectors which work on 110-220v outlets
Input
■
Nominal frequencies: 50/60Hz
■
Nominal voltage range: 100-120/200-240 VAC
■
Maximum current AC RMS: 13.8A @ 100 VAC
■
AC operating range: 90-264 VAC
Output
■
3.3 VDC STBY: 3.0A
■
+12 VDC: 86.7A
Power dissipation
■
Max power consumption: 1235.3 W
■
Max heat output: 4212 BTU/hr
■
Volt-Ampere rating: 1261 VA @ 240 VAC, 0.98P.F.
Internal Components
The chassis has the following boards installed. Field-replaceable units (FRU) should only be
replaced by trained Oracle service technicians.
■
PCIe Risers
- Each riser supports two PCIe cards that are customer-replaceable. There are
two risers per system, each attached to the rear of the motherboard.
7120
Chapter 2 • Hardware Maintenance