With the ejector arms in the full open position, align the new SIM board with the open slot and
slide it into the tray until the ejector arms contact the tray connectors and begin to swing
closed.
Swing both ejector arms in until they are flush with the SIM board panel to seat the board.
Tighten both captive screws to secure the board.
Reconnect the SAS interface cables to their original locations.
Wait approximately 60 seconds for the SIM board to complete its boot process, at which time
the Power LED should be solid green and the SIM locate LED should be off.
Faults
Hardware Faults
This section describes connecting to the controller Service Processor (SP) and configuration
considerations for maximum serviceability. In rare cases, faults associated with uncorrectable
CPU errors are not diagnosable or displayed in the controller. These faults will be preserved by
and observable on the ILOM. The following sections describe how to connect to and manage
faults for these cases.
7
8
9
10
11
Faults
Chapter 2 • Hardware Maintenance
93