Fine Tune the VLAN Setup
Mac Based Support : Disabled
Subnet Based Support : Disabled
Port-and-Protocol Based Support : Enabled
Default Priority : 0
Dot1x Protocol Tunnel Status : Peer
LACP Protocol Tunnel Status : Peer
Spanning Tree Tunnel Status : Peer
GVRP Protocol Tunnel Status : Peer
GMRP Protocol Tunnel Status : Peer
IGMP Protocol Tunnel Status : Peer
Filtering Utility Criteria : Default
Port Protected Status : Disabled
6.
Add an untagged port using the alternate method.
a.
Type these commands.
For example, add 10 GbE port
Ex0/4
to
vlan 4
as untagged.
SEFOS#
configure terminal
SEFOS(config)#
vlan 4
SEFOS(config-vlan)#
ports extreme-ethernet 0/4 untagged extreme-ethernet 0/4
SEFOS(config-vlan)#
exit
SEFOS(config)#
interface extreme-ethernet 0/4
SEFOS(config-if)#
switchport pvid 4
SEFOS(config-if)#
end
b.
Verify the port VLAN ID.
SEFOS#
show vlan port config port extreme-ethernet 0/4
Vlan Port configuration table
-------------------------------
Port Ex0/4
Port Vlan ID :
4
Port Acceptable Frame Type : Admit All
Port Ingress Filtering : Enabled
Port Mode : Hybrid
Port Gvrp Status : Disabled
Port Gmrp Status : Disabled
Port Gvrp Failed Registrations : 0
Gvrp last pdu origin : 00:00:00:00:00:00
Port Restricted Vlan Registration : Disabled
Port Restricted Group Registration : Disabled
Mac Based Support : Disabled
Subnet Based Support : Disabled
22