Goldpress 5 • User guide
EN
Standard supplied equipment for GoldPress 5:
Side stops
Rear stop
Magnetic stop
Container for holding printing foil
Foil cutter
O.Master frame Frame GP5
O.Frame Stand Holder GP5
Phillips screwdriver PH1
Typeface font tweezers
Additional equipment:
Frame O.Frame GP5:
Channel Vertical GP5, 5L5 Vertical, 5L4, 5L5, 3L9,
1L9-2L4, 1L9-1L5, 1L4-1L16, 1L16-1L5. Adapter for gilding
on channels O.Goldchannel Base GP5/GP4-2017
Mounting plate matrices
O.Screw Matrix Base MP02/GP5
O.Matrix Base MP/MP02/GP5/GP4/IP
O.Matrix Base MP02/GP5
DEFECT
POSSIBLE CAUSE
REMEDY
The display does not indicate
a temperature
The plug is not connected
to mains
Insert the plug to mains socket
Lack of voltage in a socket
Connect the machine to
another socket
The device is damaged
Contact the supplier
The device does not achieve a
desired temperature or exce-
eds it significantly
Check what temperature
has been set
Set a suitable temperature
The device is damaged
Contact the supplier
Pale dots appear within hot
stamped inscription
Too low temperature
Increase temperature
Too short time of stamping
Increase stamping time
Too low pressure
Increase the pressure
(turn clockwise the knobs
of the base plate (22)
Stamped letters are blurred,
traces of paint are visible
beyond letter edges
Too high temperature
Reduce temperature
Too long time of stamping
Reduce stamping time
Too high pressure
Lower the pressure
(turn counter-clockwise
the knobs of the base
plate (22)
15
MAINTENANCE
The equipment does not need lubricating or periodical service. The points that need lubrication
have been greased and sealed in the factory. The housing is powder coated and baked hard.
Cleaning use only domestic detergents. Do not use any petroleum or solvent based cleaners!