A12.1095

 

Research Scientific Laboratory Microscope, 

Full-Auto Motorized 

Instruction Manual 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

This manual is for users of A12.1095 scientific research microscope. To ensure your safety, 

obtain

 

optimum  performance,  and  to  familiarize  yourself  fully  with  the  use  of  this 

microscope, we recommended that you study the instruction manual carefully.   

 

Summary of Contents for A12.1095

Page 1: ...ed Instruction Manual This manual is for users of A12 1095 scientific research microscope To ensure your safety obtain optimum performance and to familiarize yourself fully with the use of this micros...

Page 2: ...ing the extensional function board 11 3 11 Computer control signal interface and photo function key 11 3 12 Additional function keys 12 3 13 Touch screen 12 4 Installation 13 4 1 Installing Diagram 13...

Page 3: ...nvection air which is used for cooling 6 Make sure the instrument is earthed to avoid lightning strike 7 Check the input voltage be sure the input voltage which signed in the back of the microscope is...

Page 4: ...or potential sources of electrical sparks and use them in a drafty room as possible as you can 5 Don t use organic solvent to wipe the non optical elements when you need to clean use the soft detergen...

Page 5: ...4 1 Components Name A12 1095 Objective Eyepiece Viewing Head Condenser Nosepiec e Main Body Stage...

Page 6: ...peed control button 5 Condenser adjustment knob 6 Switch button for upper and lower light 7 Brightness adjustment knob 8 Condenser 1 2 3 4 5 6 7 8 9 10 11 12 13 9 LCD touch screen 10 Aperture iris dia...

Page 7: ...r condenser 3 Condenser adjustment knob 4 Adjustment hand wheel 5 Photo button 6 Filed iris diaphragm adjustment ring 7 Shortcut 8 Tension adjustment ring for lamp housing 9 Ground lever 10 Lamp housi...

Page 8: ...t on the top is opening the symbol is When the light switch button is push out the light on the bottom is opening the symbol is 3 3 Light socket Fig 3 As shown in Fig 3 there are red dots in the socke...

Page 9: ...e the objective may collide with the specimen 3 5 Adjusting the interpupillary distance Fig 5 The interpupillary distance range 47mm 78mm While looking through the eyepieces adjust for binocular visio...

Page 10: ...e converted to other magnification objective to achieve focusing without damaging the specimen 2 When camera is needed Push the light path switch selector rod as shown in Fig 7 to the end for binocula...

Page 11: ...he field iris diaphragm inscribed with the field of viewing That means the condenser is centred correctly 7 Slightly increase the field iris diaphragm in reality operation to make the image circumscri...

Page 12: ...out the standard bright and dark field board then inset the extensional function board into the slot and tighten the screw 3 11 Computer control signal interface and photo function key Fig 12 13 Conn...

Page 13: ...croscopes has a set of supporting software For the specific operation of the software please refer to the software manual The function keys can be used in combination with the touch screen Please refe...

Page 14: ...installation sequence of the components The number in the figure shows the assembly steps Before installing be sure every components is clean do not score any parts or glass surface Keep well with hex...

Page 15: ...l groove of the stage holder with the dovetail bulge of the frame and slide down naturally until lower limit screw is limited Then the screw I in Fig 2 is screwed inward with a wrench 4 2 2 Installing...

Page 16: ...photo attachment or C mount 0 5 Mount the photo attachment or 0 5 C mount according to the assembly path into the connecting seat of the trinocular viewing head and tighten the screw V During the inst...

Page 17: ...en instruction manual for specific operation Clean the objectives regularly for lens is susceptible to dust When operating use 10 magnification objective to search and focus specimen firstly then repl...

Page 18: ...erface into the ternary camera barrel to an appropriate position Then screw in the number XI bolt to fasten the camera interface In order to ensure the appropriate position of camera interface the spe...

Page 19: ...ctric stage 270 210mm Moving range 125 75mm Illumination 3W LED lamp Condenser Abbe condenser NA0 9 0 1 Software Image software Scopeimage10 Photo attachment Video attachment C Mount 1 C Mount 0 5 Pol...

Page 20: ...the reverse side Turn it over Dry objective has oil on it especially for 40X objectives Wipe the oil A lens the objective condenser eyepiece or collector is dirty Clean it Immersion oil is not used wi...

Page 21: ...en display magnification The objective is not properly installed to the specified converter hole or the screen setting is inconsistent with the actual situation The objective is re installed to the co...

Page 22: ...the instructions A12 1095 Stage is not working properly Improper line connection Check the internal connections and reconnect well Initialization cannot stop after turning on Improper control board R...