8.1.3
Cleaning if Necessary
The switch can develop a buildup on the sensor tip. Remove the sensor from the piping and clean the
sensor tip using a soft cloth. If stubborn build-up exists, it should be removed using vinegar based
cleaner. Figure 8-2 shows the Coolant Flow Meter Sensor tip removed from the pipe system.
Figure 8-2: Coolant Flow Meter Sensor Tip
8.2
Recovering from Error Messages
A coolant flow fault, low air pressure, unreferenced axes or Z Axis over travel may cause error messages
to appear on the user interface. Press the
RESET
button to clear messages, after action to correct the
error has been taken.
For example: If you see a low air pressure error message, it may be because your air compressor was
shut off at some point causing the machine to fault out. If your compressor has already been turned
back on, the only step needed to clear the error is to hit the
RESET
button. If the software has been
closed, the axes are no longer referenced. This will cause an error message to appear. Press the
RESET
button, turn the
SERVOS
on, then
ZERO
and then
CYCLE START
. This will reference the axes and your
machine will be ready for production.
Contact OptiPro Service if additional support is needed.