11
Function
Parameter Settings/Options
Default
Overload Range
C24
00 = turn off overload range
01-99d = overload range setting d = division
9
Negative Display
C25
0 = -9d
10 = -10% max. capacity
20 = -20% max. capacity
10
Standstill Time
C26
0 = quick
1 = medium
2 = slow
1
Standstill Range
C27
1 = 1d d = division
2 = 2d
5 = 5d
10 = 10d
2
Digital Filter
(for filtering moving
weight such as
animals)
C28
0 = turn off dynamic filter
1 = 1 digital filter strength
2 = 2 digital filter strength
3 = 3 digital filter strength
4 = 4 digital filter strength
5 = 5 digital filter strength
6 = 6 digital filter strength
Note: The higher the number, the higher the filter
strength
0
Noise Filter
C29
0 = turn off noise filter
1 = 1 digital filter strength
2 = 2 digital filter strength
3 = 3 digital filter strength
2
Print Time and Date
C30
0 = yy.mm.dd
1 = mm.dd.yy
2 = dd.mm.yy
3 = yy.mm.dd