OPTICON
User's manual
PHL-7000 series
3-3
None
Disable beep after scanning bar code.
One Time
Beep one time after scanning bar code
(default).
Two Times Beep two times after scanning bar code.
Select the bar code data transfer method
Disable Data
from
bar
code reader is ignored.
Keybd Message
Type
Writing
Data from bar code reader is send as
keyboard data to the application which
currently has the focus (default).
Select the bar code reading mode.
Single
read
When a bar code has been decoded, the
reader will be turned OFF. The reader
must be triggered again to read another
bar code (default).
Read mode
Multiple
read
When a bar code has been decoded, the
reader will stay ON for the time as set by
‘Read time’ options. The same bar code
can only be decoded again after the label
has not been detected for a number of
scans.
The length of the period that the reader is ON after the
trigger switch is pressed, or (in multiple read mode),
after a label has been read.
0 sec
Reader will stay on as long as the trigger
switch is being pressed.
1 sec
1 second
2 sec
2 seconds (default)
3 sec
3 seconds
4 sec
4 seconds
5 sec
5 seconds
6 sec
6 seconds
7 sec
7 seconds
Read time
8 sec
8 seconds