USER MANUAL
DVI MATRIX ROUTER
– ODM1818
ODM1818 Manual - Edition 7a
Page 14
2.6.8
EDID SAVE: press FUNCTION eight times
Reads EDID from connected displays and stores information to Input ports
EEPROM.
========= EDID SAVE ========
I: 1. 2. 3. 4. 5. 6.
O: DE. DE. ED. ED. 3. DE.
Row “I” represents input port EEPROM number while “O” represents stored EDID
information.
For example, the fifth column
„3‟ represents the EDID information from connected
display at Output port 3 was saved in Input port 5 EEPROM.
“DE” (Default) is the factory default EDID (VESA standard 1920 x 1080 @ 60Hz).
The Under Bar mark represents selected and activated.
Pressing output
„1~18‟ button changes the number from 1 to 18.
Input 15 and 16 buttons make the page move. (Previous and next).
Input 17 and 18 buttons make the Under Bar move to left and right, respec-
tively.
Press
ENTER
button to complete the configuration, store the information and
execute the process.
2.6.9
COMMNAD TYPE: press FUNCTION nine times
Command type function is used to operate ODM1818 with controller that uses
their own command. The default setting is DS-1818M SE mode and all of user
manual is based on DS-1818M SE mode. For more details, please contact
tech-
.
2.6.10 FACTORY MODE: press FUNCTION ten times
Press 1 and
ENTER
to reset and restore factory default settings and turn off and
on the ODM1818.
2.7 Serial Communication
2.7.1
HyperTerminal
ODM1818 provides command line interface through serial port, RS-232.
Hyper Terminal is effective serial emulation software to communicate with
ODM1818 when Microsoft Windows operating system is used to control
ODM1818.
Hyper Terminal connection procedures:
1) Connect the ODM1818 to a PC as described in section RS-232 Control.
2) Select Start > Programs > Accessories > Communications > HyperTerminal