5
Specifications
Accessories : AA battery x 2pcs. (for checking operations), Instruction manual (this document)
exclusive protective case, USB cable (Only for PT-U80)
Optional : Blackbody tape
PT-U80
PT-S80
Model
Measuring range
- 30 to 600°C
□
30/1000mm (D:S=33:1)
Field of view
Si lens
Optics
Sensing element
Thermopile
8 to 14
μm
Wavelength
0.5sec. / 90%
Response time
Accuracy (
ε
0.95)
- 30.0 to 0°C : ± 3°C, 0.1 to 200°C : ± 2°C,
200 to 600°C : ±1% of reading value
±1°C of reading value
Repeatability
Display resolution
- 30.0 to 199.9°C : 0.1°C, 200 to 600°C : 1°C
Coaxial laser marker (Class 2)
Sighting method
15 seconds
HOLD time
Continuous measurement mode
ON / OFF Selectable
–
–
1-point memory
35-point memory
USB output
Memory
High/Low Alarm LED/Buzzer
Alarm LED/Buzzer ON/OFF Selectable
Emissivity (
ε
) Adjustment
0.95/0.85/0.70 Selectable
ε
Adjustable
(0.30 to 1.20/0.01step)
Temperature unit
°C / °F (Selectable)
NOR / MAX / MIN
Display function
AA Battery x2pcs.
Power supply
15 Hours (with max load)
Battery life
Ambient temperature
0 to 50°C
Ambient humidity
35% to 85%Rh (Without due condensation)
Storage temperature/humidity
-10 to 60°C/35% to 85% Rh
ABS/TEEE
Material
H x W x D = 182 x 56 x 38 mm
Dimension
Approx. 250g (Including batteries)
EMC Directive (2014/30/EU),RoHS Directive (2011/65/EU),China RoHS (M
II
T Order No.32)
FDA (21 CFR 1040.10 and 1040.11)
(expect for deviations pursuant to Laser Notice No.50)
Consumer product safety Act.(PSC Mark)
EN 61326-1:2013,
IEC 60825-1:2007,2014
Weight
Applicable regulations
Applicable standards
※
1 The measurement accuracy in the specification is limited to the calibration conditions of our factory.
※1
For China RoHS, please refer to http://www.optex-fa.com/rohs_cn/
Summary of Contents for PT-7LD
Page 7: ...7...
Page 23: ...7...
Page 34: ......
Page 40: ...6 There is no button to turn ON OFF the supper supply Name of Components...
Page 41: ...7...