background image

ENGLISH

FRANÇAIS

DEUTSCH

IT

ALIANO

ESP

AÑOL

PORTUGUÊS

EN-6

10

Connect the connectors.

Notes>>

11

Transmitter

1.

2.

3.

 

 

Separate box side

Main unit side

Red

Black

White

Yellow

Green

Blue

Brown

Orange

Grey

Red:   Power input (+)

Black:   Power input (-)

White:   Alarm

Yellow:  Alarm

Green:  Trouble

Blue:   Trouble

Brown:  Tamper

Orange: Tamper

Grey:   Tamper

Install the transmitter and 

attach the separate box cover.

12

For the subsequent procedure, refer to 

steps 13 to 17 (page 5). 

2-5

SIDE-BY-SIDE AND TOP-TO-BOTTOM METHOD

6

Open the knockout.

Main unit

 

(Back surface)

Separate box

 

(Back surface)

Separate box

For the stacking method, refer to 2-4.

7

Pull the wire connectors through wiring 

knockout. 

Wall mounting

knockout

Wall mounting

knockout

Wiring knockout

Wiring knockout

(For side-by-side method) 

8

Mount the bracket and the separate box to the wall.

Screw (3 × 20 mm)

Screw (3 × 20 mm)

Hold the top part of the bracket 

and mount the main unit.

1.

3.

2.

Mounting

height:

0.8 to 1.2 m

(2.6 to 3.9 ft.)

100 mm

(3.94 inches)

83.5 mm

(3.29 inches) 

Wiring knockout

(For top-to-bottom method)

• The tamper output is not exclusive. The anti-masking and 

tamper circuits share the trouble output.

• For the wall tamper wiring connection (option), refer to 

5-1.

• If the tamper connection is made between the main unit 

and the separate box, cut the jumper wire (orange) as 

illustrated. Otherwise, neither the separate box tamper 

nor the option wall tamper switch will be activated. 

Conversely, if the tamper connection is not made 

between them even the jumper cutting situation, the 

trouble signal will remain activate.

Double-sided 

tape

Double-

sided 

tape

Side-by-side

method

Top-to-bottom

method 

Sponge

Sponge

 

9

Note>>

• Be careful not to pinch wires.

Wiring

Summary of Contents for Fit Series

Page 1: ...2 2 2 TRANSMITTER PREPARATION 3 2 3 BEFORE WALL MOUNTING 3 2 4 STACKING METHOD 4 2 5 SIDE BY SIDE AND TOP TO BOTTOM METHOD 6 3 WALK TEST 3 1 WALK TEST 7 4 DIP SWITCH SETTING 4 1 WALK TEST MODE 7 4 2 B...

Page 2: ...3 9 m ft 0 1 2 3 4 5 0 5 10 15 ft 0 5 10 15 m 0 1 2 3 4 5 2 6 0 ft 3 3 3 9 0 8 0 m 1 0 1 2 0 1 2 3 4 5 0 0 0 5 5 5 10 10 10 15 15 15 1 1 1 2 3 4 5 m ft ft m 2 4 5 3 Adjustable range 95 by 5 pitch Adju...

Page 3: ...1 Open the main unit cover 2 Remove the fixture Fixture 4 Open the separate box Hold the top of the bracket and remove the main unit 5 Select the mounting method Stacking method 2 4 Side by side metho...

Page 4: ...xclusive The anti masking and tamper circuits share the trouble output For the wall tamper wiring connection option refer to 5 1 If the tamper connection is made between the main unit and the separate...

Page 5: ...h 1 WALK TEST MODE is set to ON TEST before attaching main unit cover Note The battery life will be shortened unless the DIP switch 1 is set to OFF To use the LED in normal operating condition set the...

Page 6: ...t For side by side method 8 Mount the bracket and the separate box to the wall Screw 3 20 mm Screw 3 20 mm Hold the top part of the bracket and mount the main unit 1 3 2 Mounting height 0 8 to 1 2 m 2...

Page 7: ...itch 4 LED setting The DIP switch 2 BATTERY SAVING TIMER setting is active Function Position NORM The switch is set to ON TEST by factory default Note The detector will not generate alarms at interval...

Page 8: ...d the main unit cover are attached Please be careful not to leave any object within 1 m from the unit The trouble is output after 20 seconds ON LED OFF LED ON Function Position OFF Factory default LOW...

Page 9: ...nd close the separate box Note Check that the warm up period is started Open the separate box and disconnect the transmitter connector It is not necessary for the main unit to be opened 5 OTHERS 6 BAT...

Page 10: ...witch 10 VDC 0 01 A max Enable During DIP switch 1 WALK TEST MODE or DIP switch 4 LED ON Disable During normal operation Light Blink Warm up alarm masking detection FTN RAM only Connector for POWER an...

Reviews: