- 67 -
Using the internal web pages
Receiver #
Source port filter
Can be used to filter incoming data traffic. With multiple signals
sent to the same IP address and destination port number,
Source port filter
can be used to filter the input, i.e. to accept
only data from the transmitting port specified here. The filter
will not be active if set to 0 (the default and recommended
setting).
Connection priority
Parameter intended for use with the MX Software Development
Kit.
Reorder buffer size
Used to reorder incoming packets.
Stream fail delay
[0…10000] ms. Default: 300 ms.
FloodGuard enable
Should be on, to enable the sending of control messages. For
more information about FloodGuard, see section 7.7.2.
FloodGuard tx interval [1…1000]
ms.
Stream type
UDP
,
UDP + NKF
. The UDP + NKF option will add an extended
RTP header for Optelecom-NKF applications requiring extra
information.
Link lost alarm timeout [1…1000] s. Time in seconds before alarm sent; default=10s.
Figure 7.53 Advanced settings, Receiver #