Biopel MINI - Installation and Operation Instructions
47
consumption during boiler operation.
14.
BIOPEL ONLINE
Every Biopel MINI boiler can be connected free of charge to the OPOP online server, which runs an application for remote
management of the boiler and heating system via the internet using your web browser. Connecting the boiler to this online
system is very simple, see points below.
Connect the control unit to your internet receiver (modem or router). For the connector in the external socket, see
the chapter Electrical Connection of Accessories.
In the v9 MINI control unit settings, display the Registration Code, in the Registration function in the Installation Menu,
Ethernet Module. Write this registration code down, you'll need it later.
This code has a limited validity, so after displaying the code, we recommend that you proceed immediately to register
the boiler, see the next points of the procedure.
Start the internet browser on your computer and enter the following address: opop.emodul.eu
Click on New User and register the user to the OPOP online server.
After successful registration, log in to the system using the username and password you chose earlier during the new
user registration.
Once connected, you must register your boiler by clicking on New Module in the Settings tab (top right).
During the registration of the new module (boiler), enter all the information requested, including the registration code
you wrote down earlier.
Once the module registration is saved, our online server connects to your boiler and all data from the boiler is
uploaded to the server within seconds.
Now your boiler is fully connected to the OPOP online server and you can take full advantage of all the functions that remote
boiler management offers via the internet. OPOP spol. s.r.o. technicians are ready to deal with any questions you may have.
15.
FIRMWARE UPDATES
Each v9 MINI unit can be updated using a USB key. OPOP spol. s.r.o. regularly releases new versions of the unit software for
free download. New versions usually contain new features and options that increase the boiler's automation and provide more
control options for the heating system. Consult the possibility of using new software updates with your installer or directly with
an OPOP spol. s.r.o. representative. The installation procedure is very simple, see points below.
Upload a file with the extension ".bin" to the USB key.
Switch off the boiler using the main switch on the top of the boiler.
Insert the USB key into the connector on the side of the display.
Switch on the boiler using the main switch.
Wait until the installation is complete (the unit displays the standard basic panel) and remove the USB key.
The v9 MINI control unit and the v9 MINI display are updated.
The USB key in use must be formatted in the FAT32 file system for proper file upload. To check the system file your USB key is
formatted in, right-click the USB key icon in your computer's operating system and enter Properties.
Caution: when uploading new software, the control unit settings will be reset to the original, factory default values. Therefore,
it is necessary to perform all settings again, including the so-called First Boiler Start-Up.
16.
OPERATING AND ALARM MESSAGES
Below is a list of common questions we encounter. These relate to the boiler installation and operation. Read these questions
carefully, they may help you in dealing with specific situations you may encounter.
1.
Alarm: Feeder sensor damaged
It is safety sensor on the burner. Check the connection of the sensor in the burner circuit board and in the control unit
in the "Feeder sens." output.
2.
Alarm: CH sensor failure
CH sensor connected in output "CH sens." It is damaged or not connected.
3.
Alarm: DHW sensor failure