Safety and Installation Manual
1.0
General Information
We wish to thank you for the preference on Open Renewables
®
High Quality Photovoltaic Modules.
This manual provides important informations to installers and other solar industry professionals.
End users will find useful information how to operate with Open Renewables
®
High Quality Photovoltaic Modules on the
“User Manual”.
Please read carefully these instructions and follow them strictly.
The products are not intended to be used in any purpose different then the purpose stated on this handbook. Please
contact your installer for further information.
This manual applies for the following products:
Open 1XX-ME48
175-ME48, 180-ME48, 185-ME48, 190-ME48, 195-ME48, 200-ME48,
205-ME48, 210-ME48
Open 2XX-ME60
220-ME60, 225-ME60, 230-ME60, 235-ME60, 240-ME60, 245-ME60,
250-ME60, 255-ME60, 260-ME60
Open 2XX-PC60
220-PC60, 225-PC60, 230-PC60, 235-PC60, 240-PC60, 245-PC60, 250-PC60
Open 2XX-PQ60
220-PQ60, 225-PQ60, 230-PQ60, 235-PQ60, 240-PQ60, 245-PQ60,
250-PQ60, 255-PQ60, 260-PQ60
Open 2XX-PS60
220-PS60, 225-PS60, 230-PS60, 235-PS60, 240-PS60, 245-PS60,
250-PS60, 255-PS60, 260-PS60
➢
Before handling, installing and operating Open Renewables
®
PV modules all instructions provided with this
manual shall be understood. Save this document and hand over a copy to the PV system owner.
➢
Follow all applicable national and international regulations and standards.
➢
When unpacking and installing PV modules and BOS components unauthorized people shall be kept in a save
distance to the construction site.
➢
When exposed to light (even under low light conditions), PV modules produce almost full voltage. Current and
power increase with light intensity.
➢
Under operating conditions, a PV module is likely to produce more current and/or voltage than reported at
Standard Test Conditions (1000 W/m2, AM 1.5 and 25 °C cell temperature). Accordingly, the values of short-
circuit current (Isc) and open-circuit voltage (Voc) given on the module label should be multiplied by a factor
of 1.25 when determining component voltage ratings, conductor current rating, fuse sizes, and size of controls
connected to the PV output.
2.0
Product specification
2.1
Application
➢
Do not direct artificially concentrated light on Open Renewables
®
PV modules.
➢
Open Renewables
®
PV modules must not be used on vehicles.
➢
Open Renewables
®
PV modules must not be mounted on locations where aggressive substances could harm
them (particularly salt or salt water).
➢
Open Renewables
®
PV modules must not become submerged in water.
➢
Open Renewables
®
PV modules must not be disassembled or modified. Any unauthorized modification of the
product will void the warranty.
Page 3 of 12
Document ID: OR-MA-2XX Revision 4.50 04-03-2013
© 2013 Open Renewables
®
– All rights reserved
EN
Applicable only in European Union