• The power supply line for the fan 

requires a multi-pole circuit breaker 

/ isolation switch with a minimum 

contact break gap of 3 mm (ref. PN-EN 

60335-1)!

• The mains system, voltage and 

frequency must match the nameplate 

ratings of the fan.

Dimensions

The dimensions of specific fan models 

are shown on page 2.

MAINTENANCE AND CLEANING

Servicing and maintenance

• Use protective footwear and gloves 

during maintenance!

• During all maintenance and ser-

vicing works the electrical and OHS 

regulations (PN-IEC 60364-3) must be 

observed.

• Before servicing the fan, isolate it 

from the mains voltage with the circuit 

breaker. Secure the circuit breaker 

against inadvertent operation!

• The fan ductwork must be clear of for-

eign bodies: hazard of injury by objects 

blown out at a high speed!

• Do not attempt any maintenance when 

the fan is running or at live voltage!

• If excessive vibrations are felt or 

heard, have the technical inspection 

carried out by a qualified electrician.

• The maintenance intervals depend on 

the actual contamination of the fan rotor 

and must not be longer than 6 months!

• Check the fan rotor for cracks.

• The manufacturer shall not be liable 

for any damage resulting from unpro-

fessional repairs.

• For equipment where engines with 

ball bearings have been used with 

“lifetime lubrication”, the engine does 

not require lubrication.

Cleaning

Electrocution hazard by damaged wiring 

insulation!

Before attempting to clean the fan, 

isolate it from the mains voltage with 

the circuit breaker.

Secure the circuit breaker against 

inadvertent operation!

• Clean the visible parts of the housing 

with a damp cloth.

• Do not use aggressive paint solvents!

• Do not clean with a high pressure 

cleaner or strong jets of water!

• Clean carefully to prevent water from 

entering the motor or the terminal box.

• Always keep the guard grille at the 

suction side clean.

Do not dispose of waste electrical 

equipment with household waste.The 

crossed-out wheelie bin symbol on this 

product means that it is waste of elec-

trical and electronic equipment (WEEE) 

at the end of its operating life and shall 

not be disposed with household waste. 

The crossed-out wheelie bin symbol 

speces that the product is subject to 

obligatory waste segregation schedules 

for proper disposal. The product is 

made from recyclable materials and 

components. The product user is 

required to return the product which 

has become WEEE to a WEEE collection 

unit. The operators of WEEE collection 

units, including local WEEE locations, 

product resellers and other WEEE 

collection locations managed by local 

authorities form a proper waste dispos-

al system. Proper WEEE disposal helps 

avoid harmful effects to humans and 

the environment from the risk caused 

by hazardous components this product 

may contain. The household plays an 

important role in contributing to reuse

and recovery, including recycling, of 

used up appliances, and it is the stage 

where attitudes are created that impact 

the preservation of the common being 

the clean natural environment. House-

Summary of Contents for WKA 100

Page 1: ...1 User Manual DUCT FAN WKA 100 125 150 English Finnish Swedish Estonian Norwegian...

Page 2: ...2 34 89 100 100 36 90 125 125 34 90 150 150 WKA100 WKA125 WKA150...

Page 3: ...ble clamp kaapelikiinnike kabelkl mman selle klmabri kabelklemme 5 electronic module elektroniikkamoduli elektroniska timermodulen elektroonikamoodulil elektronikkmodul 6 inlet tuloputki inloppet imip...

Page 4: ...ion and connection with the building electrical system The building electrical system connected to the fan must be capable of breaking live voltage contact on all switching poles to fully isolate the...

Page 5: ...e models with the supply cable attached Do not use the fan to handle the air with the following content viscous contaminants prone to deposi tion in the fan corrosive contaminants which may degrade th...

Page 6: ...to the model installed Protect the cable against sliding out using the clamp 4 and the screws 3 Verify that the power cable cores are held tight by the terminals Attach the controller s cover 2 to the...

Page 7: ...e attempting to clean the fan isolate it from the mains voltage with the circuit breaker Secure the circuit breaker against inadvertent operation Clean the visible parts of the housing with a damp clo...

Page 8: ...alvoo tai neuvoo heit laitteen turvallisessa k yt ss niin ett he ymm rt v t olennaiset k ytt riskit T m tuote ei ole leikkikalu eik lapset saa leikki sill Lapset eiv t saa puhdistaa tai huoltaa tuotet...

Page 9: ...uoritustasorajoitusten puitteissa Liit ilmanpoistopuhallin rakennuk sen verkkovirtaan s hk j rjestelm seuraavalla virtakaapelilla NYM O 2x1 5 mm2 H07V K 2x1 5 mm2 tai NYM O 3x1 5 mm2 H07V K 3x1 5 mm2...

Page 10: ...mpi eristyskerros vir tajohdosta ja poista eristyst 4 mm johdoista J rjest virtajohto ja liit se asen netun mallin s hk kytkent kaavion mukaisesti Est virtajohdon luistaminen ulos kiinnikkeell 4 ja ru...

Page 11: ...iheutuneista vahingoista Laitteissa joissa moottorin kuula laakerit ovat kestovoidellut moottori ei vaadi voitelua Puhdistus Vioittuneesta johtojen eristyksest aiheutuva s hk iskunvaara Erist puhallin...

Page 12: ...rodukten utan vuxens tillsyn Fl kten r avsedd att installeras och instrueras permanent med byggnadens elektriska system Byggnadens elek triska system som ansluts till fl kten m ste kunna bryta str msp...

Page 13: ...typskylten Anslut fr nluftsfl kten till byggnadens eln t elektriskt system med f ljande str mkabel NYM O 2x1 5 mm H07V K 2x1 5 mm eller NYM O 3x1 5 mm H07V K 3x1 5 mm maximal ytterdiameter 9 5 mm bero...

Page 14: ...isoleringen fr n ledningarna Anordna str mkabeln och anslut i enlighet med det elektriska kabel dragningsschemat till mpligt f r den installerade modellen Skydda kabeln fr n att glida ut med hj lp av...

Page 15: ...till f ljd av oprofes sionella reparationer F r utrustning d r motorer med kullager har anv nts med livstidss m rjning beh ver man inte sm rja motorn Reng ring Fara f r elst tar genom skadad kabeliso...

Page 16: ...igpingeolukorra tekkimisel katkestama ventilaatori t ielikuks lahutamiseks k ikide l lituspooluste pingekontakti vastavalt asjakohastele elektriohutusn uetele Ventilaator on kavandatud kasutamiseks pa...

Page 17: ...e kasutage ventilaatorit allj rgne va koostisega hu k itlemiseks hk mis sisaldab kergesti ventilaatori pindadele kogunevaid kleepuvaid osiseid hk mis sisaldab s vitavaid aineid mis v ivad ventilaatori...

Page 18: ...abli juhtide kinni tuse pingsust klemmides Paigaldage kontrolleri kate 2 kruviga 1 ventilaatori kere keskosale L kake ventilatsioonitorud ventilaatori imipoole 6 ja survepoole 7 hendu sosa peale ning...

Page 19: ...itsel liti soovimatu kasutamine Puhastage kere n htavad osad niiske lapiga rge kasutage tugevatoimelisi lahusteid rge kasutage puhastamiseks k rg survepesurit ega tugevat veejuga Puhastage hoolega v l...

Page 20: ...tilkobling til bygningens str mnett Bygningens elektriske system som er koblet til viften m v re i stand til bryte str mf rende spenningskontakt p alle kontaktpoler slik at viften isoleres helt fra st...

Page 21: ...som leveres gjelder ikke for modeller med p montert str mkabel Ikke bruk viften for h ndtere luft med f lgende innhold flytende forurensning som lett kan avsettes i viften korrosiv forurensning som k...

Page 22: ...modellen som er installert Sikre kabelen slik at den ikke glir ut Bruk klemmen 4 og skruene 3 Kontroller at str mledningens ledere sitter godt i klemmene Fest kontrollenhetens deksel 2 til den midtre...

Page 23: ...g krever ikke motoren sm ring Rengj ring Skadet isolasjon medf rer fare for elektrisk st t F r du pr ver rengj re viften m den isoleres fra nettspenning med effektbryteren Sikre effektbryteren mot at...

Page 24: ...av det felles godet som rene naturomgivelser er Husholdninger er blant de ledende forb rukerne av sm husholdningsapparater og utstyr En rasjonell administrasjon av drift og kassering av sm husholdnin...

Reviews: