
7. Hardware
-
to
-
Hardware Connection Function
7. 1 Precautions for Hardware
-
to
-
Hardware Connection
Function
WARNING
・
The AC adapters connected to the units of DS
-
5100 Main Unit must be connected to the outlets with
the grounding terminals grounded.
・
Connect to the outlets so that the grounding terminals have the same potential.
If there is a potential difference between the grounding terminals, a current flows between the units
of DS
-
5100 Main Unit, which may result in failure. Before using, be sure to check that the grounding
terminals of the outlets have the same potential.
・
Do not touch the DS
-
5000 series Data Station main unit or cables with wet hands. There is a risk of
electric shock.
・
Do not pull or bend the cables.
・
Do not step on or pinch the cable in the door, etc. There is a risk of fire or failure.
CAUTION
・
The hardware
-
to
-
hardware connection function operates normally only in the combined use with the
O
-
Solution created by Ono Sokki.
・
Note that the hardware
-
to
-
hardware connection function is unavailable on the DS
-
5000 series Data
Station with the DS
-
0532/ 0534 100kHz Input Unit.
・
Be sure to hold the connector when connecting or disconnecting the cables. Do not apply an
excessive force to the cables.
There is a risk of failure or damage.
・
When the DS
-
5000 series Data Station with the signal output unit or external input unit is used for the
hardware
-
to
-
hardware connection, the specifications, functions, etc. may be limited.
For details about limitations, refer to “O
-
Solution Instruction Manual ( Description of Functions) “.
・
Do not disconnect the connection cable when using the hardware
-
to
-
hardware connection function.
Otherwise, communication or synchronization is interrupted, causing the O
-
Solution to stop and
preventing correct measurement.
・
Note that there is no compatibility with the interface cables AX
-
9031/ 9032/ 9033 for the DS
-
3000
series Data Station. Therefore, connecting these cables does not work.
Be sure to use the hardware connection cable AX
-
9055/ 9056 dedicated for DS
-
5000.
・
For details about the hardware
-
to
-
hardware connection function, visit our website
( https:/ / www. onosokki. co. jp/ English/ english. htm) or contact your nearest Ono Sokki sales office
or the distributor where you purchased the product.
7. Hardware
-
to
-
Hardware Connection Function
7. 1 Precautions for Hardware
-
to
-
Hardware Connection Function
41
Summary of Contents for DS-0501
Page 1: ...A4 58 Specifications Instruction Manual Data Station DS 5000 Series 900000581 IM20082502 1 2...
Page 10: ...viii...
Page 14: ...Table of Contents...
Page 22: ...1 2 DS 5000 Outside Dimensions 5 5 1 Overview of DS 5000 8...
Page 62: ...A4 58 Specifications Instruction Manual Data Station DS 5000 Series 900000581 IM20082502 1 2...