MOTOR
MAGNETIC
STARTER
1 2 3 4 5
LEVER
NUT
5 4 3 2 1
LEVER
NUT
MOTOR
MOTOR
Wire 1
Wire 2
Ground Wire
Magnetic Starter Wire
Dust Sentry Wire
System Power Wire
oneida-air.com 23
Maintenance (Continued)
9. Place motors back on the motor plate. Replace the motor
hold down plate, ensure wires sit above the plate, ensure
the tabs on the motors line up with the notches on the
hold down plate.
10. Re-wire the motors.
a. There is no polarity.
b. DO NOT tamper with the grounding wire.
c. Keep wiring consistent, the same wire from each
motor should be inserted into the same lever nut.
d. Open lever and insert one wire into each hole in
lever nut. Close lever and make sure each wire is
secure.
11. Re-secure the motor hold down plate using the five 5/16-
18" Nylock Nuts.
Note: DO NOT OVERTIGHTEN. Install the provided
spacers over the threaded studs to determine the correct
depth to drive the nuts.
12. Replace the plenum plate.
13. Re-install the molded cowling and the Nylock nut that
secures it. Clean then install the filter foam on top of the
molded cowling.