Maintenance (Continued)
Replacing the Motors
The motors should be replaced while the system is
on the wall bracket. Ensure the system is powered off
and unplugged. All 3 motors should be replaced at
the same time
1. Turn off and unplug the dust collector and wait for the
fan blowers to come to a complete stop and for the dust
to settle.
2. Remove the filter foam and 5/16-18 Nylock Nut from the
top of the cowling using a 1/2" socket wrench.
3. Remove the cowling and set aside.
4. Remove the plenum plate and set aside (there is no
hardware securing the plenum plate, it is compressed
between the cowling and the motors).
5. Cut the Zip Tie securing the wires to the center threaded
stud.
6. Using a 1/2" socket wrench, remove the five 5/16-18
Nylock Nuts around the perimeter of the motor hold
down plate and set both aside. All three motors are now
fully accessible for replacement.
7. Lift up the tabs on the two lever nuts and remove all of
the wires.
8. Ensure the provided die cut gasket is installed on the
bottom of each motor by pressing the adhesive side
against the bottom of the motor.
UNPLUG YOUR UNIT BEFORE SERVICING OR CLEANING. KEEP THE TOP VENTS IN THE COWLING CLEAN.
THESE ARE FOR BOTH EXHAUST AND INCOMING COOLING AIR FOR THE MOTOR.
Summary of Contents for Supercell XSK000014
Page 2: ......
Page 31: ...oneida air com 29 Notes...