![Oneida Air Systems Supercell XSK000014 Owner'S Manual Download Page 21](http://html1.mh-extra.com/html/oneida-air-systems/supercell-xsk000014/supercell-xsk000014_owners-manual_1635523021.webp)
oneida-air.com 19
G14
G22
G22
J
H
G18
Assembly Instructions (Continued)
ONLY USE VACUUM PRESSURE RATED FLEX-HOSE AND DUCT WITH THE SUPERCELL DUST COLLECTOR.
UNDER THE SYSTEM'S HIGH SUCTION, STANDARD HOSE/PIPE MAY COLLAPSE CAUSING AFFIXED TOOLS
TO BE PULLED TOWARDS THE SYSTEM, POTENTIALLY CAUSING DAMAGE AND/OR INJURY.
30
Attach the other end of the Vinyl Tubing
(G18) onto the Nylon Elbow (G19A) installed
on the lower section of the Drum (J1). Push
the tubing onto the elbow so that all the barbs
are covered [FIG. 30].
31
Center the Drum Assembly (J) underneath
the Wall Bracket (F) and lower the Latches
(G14) so that they hook underneath the rim
of the Drum (J) [FIG. 31]. The Latches (G14)
can then be closed to lift the drum up from
the ground and seal the dust collector for
operation.
Note: Be sure to rotate the Drum (J) to ensure
that you can easily see the pre-installed fill
viewing window. The Hex Head Bolts (G17)
installed in Step 27 are guides for positioning
the Drum during latching. The back rim of the
Drum should be in light contact with both Hex
Head Bolts as the Drum is lifted up and latched.
FIG. 30
FIG. 31
32
Connect the Supercell to your tools or
ductwork using the Vacuum Pressure-Rated
Hose (H). Secure the hose in place using Hose
Clamps (G22) at both ends [FIG. 32].
Installation is complete!
G19A
FIG. 32