5.1.2. LCD Module Assembly
The assembly of MP1200 LCD module slightly differs from that of MP1500.
5.1.2.1. MP1200 LCD Assembly
The standard LCD used in MP1200 is 12.1” LVDS LG.Philip LB121S03 or its equivalent. The following
figure illustrates the steps to integrate MP1200 LCD module.
1. Attach the insulator to the inverter.
2. The inverter cable is a 4-pin to 4-pin wire with wafer connectors at both sides. Connect one end to
inverter first.
3. The inverter module is to be fixed at the right middle side of the LCD holder with the up side down.
4. Plug one end of the LVDS cable to the LCD connector at rear side of the LCD.
5. Connect the LCD’s pink-white power wires from the LCD to the inverter.
6. Retain the LCD panel to the LCD holder (3) with two PMS M3*6 screws at each side.
(1)
PMS 3*6 (4)
(2)
(3)
MP1200 LCD
MODULE ASSEMBLY