STAND: 17.06.2019
9910_Operation_Manual_STANDCONTROL_C1_Rev1v1_EN
Seite 29 von 41
If automatic movement is activated in the controller, positions such as described in section 10.1.2 can
be invoked by briefly pressing the relevant position key. The key does not have to be kept pressed the
entire time. All other functions are identical.
Automatic movement is interrupted by pressing any other key.
10.2 Collision detection STAND.GUARD G1
The STAND.GUARD G1 sensor can be used as a sensitive collision protection enhancement to the
controller. A detailed description of its functions can be found in the relevant operating manual.
If you have decided to use the STAND.GUARD G1 sensor as collision detection, you can add it, as
described in Section 8.2, to the controller system at any time in a free RJ45-port.
The controller system must be disconnected from the mains when the sensor is plugged in. The
sensor is calibrated every time it is connected to the power supply. This is the case, for example, when
the sensor is newly connected to an active controller, or a configured system including the sensor is
connected to the mains supply. For the calibration, the sensor must not be moved for at least 10 sec-
onds after the power is supplied. Otherwise, the calibration returns erroneous values and has to be
repeated.
If the sensor is disconnected from the controller, the controller can continue to be used normally. An
indication is provided to the user about the absence of the previously present sensor, by displaying the
code
. When the first attempt is made to move after disconnection of the previously present
sensor, there is an audio warning to the user from the controller in the form of 3 “click-clack” sounds.
Then, the controller moves off as usual and the displayed code is deleted.
Then, if a sensor is again connected to the controller system, and an attempt is made to move, the
controller once again emits the audio signal of 3 “click-clack” sounds. This is to draw the attention of
the user to the fact that once again, a sensor has been detected and activated. Then, the controller
moves as usual using the inserted sensor.