10.3 Cascading
Caution:
The upper end position of the desktop is pre-set in the controller. For this
reason, only those controllers that have been supplied as being suitable for the
respective desk base may be used.
Caution:
Use only controllers with identical parameter sets for cascading, since
otherwise, unforeseeable behaviour of the table could occur. The correct number
of table legs must be stored in the parameter set.
2 drives maximum can be connected to one controller. To increase this number to 4, two controllers
can be cascaded
For cascading the controllers, proceed as follows:
1. Connect the controllers with a STAND.CONNECT connecting cable.
2. Connect additional accessories as provided in Section 8.2 to the free RJ45 slots of the
controllers.
3. Connect the controllers to the mains supply (see Section 8.3).
4. Ensure that all the controllers are connected to a power supply.
5. Carry out an initialisation procedure as specified in the instructions in section 8.4.
6. If all the table legs do not move during the initialisation movement, check once again whether
all the controllers are connected to one another with the STAND.CONNECT connecting cable
and whether all the controllers are connected to the mains supply. In addition, check whether
the controllers have recognised one another. To do so, press the -button for at least 6
seconds. Then perform step 5 again.