Installation Instructions EC 2-25 Lift
(Subject to technical alterations! - Status 09/2018)
This is a translation. The German original shall prevail.
Page 24 of 50
Fig. 7 Oil check card
•
Oil colour light yellow to mid brown: Oil condition good to still usable;
•
Oil colour matches colour 3: Change oil immediately;
•
Oil colour dark brown to black: Oil unusable Change oil
6.3.3
Changing the oil
Should an oil change be necessary, follow this procedure:
1.
Place a suitable container under the oil drain plug beneath the gear unit. The oil filling for
installation in position B1 is approx. 13 litres.
2.
Carefully open the oil drain plug.
3.
After all the oil has drained, close the oil drain port tightly again.
4.
Fill new oil in using the oil dipstick opening or the bleeder valve.
5.
Observe the filling level (see 6.1.1).
6.
Only fill with the specified oil
:
Klübersynth GH 6-220 Volume: Depends on installation position (Never mix with
mineral oil!)
(Other types of oil may only be used only if OMS have given their approval)
7.
Close the filling port as appropriate with the oil dipstick or the bleeder valve.
Any oil escaping while changing the oil or due to leakage must be removed
immediately.
Used synthetic oil is special waste!