![background image](http://html.mh-extra.com/html/omron/zx-cal/zx-cal_operation-manuals_1633394174.webp)
Ratings/Specifications
Section 6-1
154
Note
1.
The response speed of the linear output is calculated as the measure-
ment period
×
(average count s 1) (with fixed sensitivity).
The response speed of the judgement outputs is calculated as the
measurement period
×
(average count s 1) (with fixed sensitiv-
ity).
2.
A Calculating Unit is required.
3.
The output can be switched between current output and voltage output
using a switch on the bottom of the Amplifier Unit.
4.
Setting is possible via the monitor focus function.
5.
This function can be set only with a Reflective Sensor Head.
6.
This function can be set only with a Through-beam Sensor Head.
Item
ZX-LDA11
ZX-LDA41
Indications
Operation indicators: High (orange), pass (green), low (yellow), 7-
segment main display (red), 7-segment sub-display (yellow), laser
ON (green), zero reset (green), enable (green)
Power supply voltage
12 to 24 VDC
±
10%, Ripple (p-p): 10% max.
Power consumption
Maximum 3.4 W (Sensor connected) (Power supply voltage: 24 V,
Current consumption: Maximum 140 mA)
Ambient temperature
Operating: 0
to 50
°
C, Storage:
−
15 to 60
°
C
(with no icing or condensation)
Ambient humidity
Operating and storage: 35% to 85% (with no condensation)
Insulation resistance
20 M
Ω
min. at 500 VDC
Dielectric strength
1,000 VAC, 50/60 Hz for 1 min
Vibration resistance
(destructive)
10 to 150 Hz, 0.7-mm double amplitude 80 min each in X, Y, and Z
directions
Shock resistance
(destructive)
300 m/s
2
3 times each in six directions (up/down, left/right, forward/
backward)
Connection method
Prewired (standard cable length: 2 m)
Weight (packed state)
Approx. 350 g
Materials
Case: PBT (polybutylene terephthalate), Cover: Polycabonate
Accessories
Instruction sheet
Z157-E1-01C.book Page 154 Thursday, August 31, 2006 5:13 PM