Through-beam Sensor Heads: FUN Mode Functions
Section 3-8
101
Default Settings
The settings are initialized to the default setting made at the factory. The
default settings are listed in the following table.
Refer to
.
Mode
Function
Initial value
FUN
Scaling values
OFF
Number of samples to aver-
age
32 samples
Hysteresis
0.5% of full scale (FS)
Hold
OFF (disabled)
Timer
OFF (disabled)
Two-sensor operation (when
two Amplifier Units are con-
nected)
OFF (disabled)
Special selection
CLOSE
Monitor focus function
4 V (20 mA): Maximum sensing dis-
tance
−
4 V (4 mA): Minimum sensing dis-
tance
Differentiation function
OFF (disabled)
Display reverse function
OFF (disabled)
ECO display function
OFF (disabled)
Limited number of display
digits
All digits displayed
Settings for non-measure-
ment
KEEP
Zero reset memory function
ON
Gain switch
METAL
Auto-scale value
100-L
T
H threshold value
100.00
L threshold value
0.00
RUN
Sub-display function
Threshold values
Reference incident level set-
ting
Not set
Zero reset function
OFF (invalid)
Z157-E1-01C.book Page 101 Thursday, August 31, 2006 5:13 PM