19

ZFV-C

Non-procedural Communication Command Reference

Revision History

Revision History

Revision code

Date

Revised contents

01

January 2006 

Original production

02

May 2006 

Function added as per software version upgrade (Ver1.30)

Summary of Contents for ZFV-C

Page 1: ...Smart Sensor ZFV C Non procedural Communication Command Reference Cat No Z244 E1 01...

Page 2: ...the ZFV C When using the ZFV C be sure to observe the following The ZFV C must be operated by personnel knowledgeable in electrical engineering To ensure correct use please read this manual thoroughl...

Page 3: ...ocedural Communication Command Reference Contents Contents Setting the Communication Specifications 2 Format 3 List of Non procedural Commands 4 Parameter List ZFV C 5 Acquiring Sending Data 10 Exampl...

Page 4: ...a USB cable or RS 232C cable to connect ZFV C controllers to external devices For the USB cable connection download and install the USB driver beforehand For the USB driver please contact your OMRON...

Page 5: ...SGET DATAGET BANKGET command The returned value consists of left aligned characters indicating the acquired value and a delimiter Example The returned value is 30 mm VERGET command The returned value...

Page 6: ...ach bank BANKSAVE BANKSAVE bank No 1 to 8 delimiter OK delimiter Receives the bank data from the controller by XMODEM protocol BANKLOAD BANKLOAD delimiter OK delimiter Sends the bank data to the contr...

Page 7: ...put range Remarks 0 36 Light brightness left 0 to 5 DATASET DATAGET compatible 0 37 Light brightness up 0 to 5 0 38 Light brightness right 0 to 5 0 39 Light brightness down 0 to 5 Unit No Parameter No...

Page 8: ...36 Area 3 39 Upper limit value 0 to 999 DATASET DATAGET compatible 2 Area 1 2 37 Area 3 40 Lower limit value 0 to 999 Unit No Parameter No Parameter Setting range output range Remarks 2 0 Judgment 2 m...

Page 9: ...5 Measurement result maximum value 0 to 509 2 6 Measurement result minimum value 0 to 509 2 7 Measurement result average value 0 to 509 2 20 Measurement count 0 to 9999999 2 21 NG count 0 to 9999999...

Page 10: ...urement count 0 to 9999999 2 21 NG count 0 to 9999999 2 22 Fault rate 0 to 99 999 2 38 Threshold 0 to 468 DATASET DATAGET compatible Unit No Parameter No Parameter Setting range output range Remarks 2...

Page 11: ...1 Measured value CHARA1 0 to 127 CHARA2 0 to 100 2 2 Measurement result maximum value CHARA1 0 to 127 CHARA2 0 to 100 2 3 Measurement result minimum value CHARA1 0 to 127 CHARA2 0 to 100 2 4 Measurem...

Page 12: ...Y reply Switch XMODEM Switch XMODEM Receive request 1 packet 128 bytes check by CRC NAK a 128 byte data BK No 1 Start of reply to the request BK No 1 sent No reply when C is being sent Data is success...

Page 13: ...reply to the request BK No 1 sent No reply when C is being sent 128 byte data BK No 1 ACK Data is successfully received Returns NAK if data receive error has occurred BK No 2 sent 128 byte data BK No...

Page 14: ...cribes an example procedure to communicate by non procedural commands using Windows standard tool HyperTerminal 1 Start up HyperTerminal HyperTerminal is located under Program Accessory Communication...

Page 15: ...edural Communication Command Reference Example of Usage 3 Set the communication conditions 4 HyperTerminal is started up 2 To facilitate command transactions set echo and other communication condition...

Page 16: ...e Settings tab and then ASCII Setup 3 Mark the following checkboxes and click OK to complete the setting 3 Set the communication conditions for the ZFV C 1 Set System2 Communication to match the above...

Page 17: ...5 ZFV C Non procedural Communication Command Reference Example of Usage 1 Enter a command and then press the return key 2 The returned value corresponding to the command is returned from the controlle...

Page 18: ...16 ZFV C Non procedural Communication Command Reference Example of Usage MEMO...

Page 19: ...17 ZFV C Non procedural Communication Command Reference Example of Usage MEMO...

Page 20: ...18 ZFV C Non procedural Communication Command Reference Example of Usage MEMO...

Page 21: ...rocedural Communication Command Reference Revision History Revision History Revision code Date Revised contents 01 January 2006 Original production 02 May 2006 Function added as per software version u...

Page 22: ...oto 600 8530 Japan Tel 81 75 344 7068 Fax 81 75 344 7107 Regional Headquarters OMRON EUROPE B V Sensor Business Unit Carl Benz Str 4 D 71154 Nufringen Germany Tel 49 7032 811 0 Fax 49 7032 811 199 OMR...