ZFV-C
Non-procedural Communication Command Reference
Parameter List (ZFV-C)
■
Color inspection (HUE)
■
Width (WIDTH)
Unit No.
Parameter No.
Parameter
Setting range/output range
Remarks
2
37
Average density
upper limit value
0 to 255
DATASET/DATAGET
compatible
2
38
Average density
lower limit value
0 to 255
2
39
Density deviation
upper limit value
0 to 127
2
40
Density deviation
lower limit value
0 to 127
Unit No.
Parameter No.
Parameter
Setting range/output range
Remarks
2
0
Judgment
-2: measurement off
-1: NG
0: OK
DATAGET compatible
2
1
Measured value
0 to 509
2
5
Measurement result
maximum value
0 to 509
2
6
Measurement result
minimum value
0 to 509
2
7
Measurement result
average value
0 to 509
2
20
Measurement count 0 to 9999999
2
21
NG count
0 to 9999999
2
22
Fault rate
0 to 99.999
2
39
Threshold
0 to 509
DATASET/DATAGET
compatible
Unit No.
Parameter No.
Parameter
Setting range/output range
Remarks
2
0
Judgment
-2: measurement off
-1: NG
0: OK
DATAGET compatible
2
1
Measured value
0 to 999
2
2
Measurement result
maximum value
0 to 999
2
3
Measurement result
minimum value
0 to 999
2
4
Measurement result
average value
0 to 999
2
20
Measurement count 0 to 9999999
2
21
NG count
0 to 9999999
2
22
Fault rate
0 to 99.999
2
38
Upper limit value
0 to 999
DATASET/DATAGET
compatible
2
39
Lower limit value
0 to 999
Summary of Contents for ZFV-C
Page 1: ...Smart Sensor ZFV C Non procedural Communication Command Reference Cat No Z244 E1 01...
Page 18: ...16 ZFV C Non procedural Communication Command Reference Example of Usage MEMO...
Page 19: ...17 ZFV C Non procedural Communication Command Reference Example of Usage MEMO...
Page 20: ...18 ZFV C Non procedural Communication Command Reference Example of Usage MEMO...