![background image](http://html1.mh-extra.com/html/omron/zfv-c/zfv-c_command-reference-manual_744108005.webp)
3
ZFV-C
Non-procedural Communication Command Reference
Format
Format
The format of non-procedural commands is as follows.
Example: Command to execute measurement
MEASURE command
* Each character is output as an ASCII code.
The format of returned values changes depending on the command.
For a description of each command, refer to "List of Non-procedural Commands."
•SYSGET/DATAGET/BANKGET command
The returned value consists of left-aligned characters indicating the acquired value
and a delimiter.
Example: The returned value is -30 mm.
•VERGET command
The returned value is output in the following format:
•Other commands
Either OK or ER is returned according to the result of the command.
The command was executed successfully:
The command was not executed successfully or the setting was NG:
The delimiter can be selected from the following three types:
CR/LF/CR+LF
M
E
A
S
U
R
E
-
3
0
CR
Z
F
V
-
C
A
1
0
1
.
0
0
0
CR
Version
O
K
CR
E
R
CR