![background image](http://html.mh-extra.com/html/omron/xpectia-fz2-30/xpectia-fz2-30_instruction-manual_1633319009.webp)
7
•
I/O Connector
No.
Wire color Mark (red)
Function
Signal name
No.
Wire color Mark (red)
Function
Signal name
Output terminal
COM IN
Input voltage
ON current *1
ON voltage *1
OFF current *2
OFF voltage *2
ON delay
OFF delay
Internal circuit
12 to 24 V DC ±10 %
5 mA min.
8.8 V min.
0.5 mA max.
1.1V max.
5 ms max.
0.7 ms max.
[Input] signals: STEP
*1 ON current/ON voltage
This refers to the current or voltage values needed to shift from the OFF
→
ON state. The ON voltage value is the potential
difference between each of the input terminals and COM IN.
*2 OFF current/OFF voltage
This refers to the current or voltage values needed to shift from the ON
→
OFF state. The OFF voltage value is the potential
difference between each of the input terminals and COM IN.
[Output] signals:
Output voltage
Load current
ON residual voltage
OFF leakage current
Internal circuit
12 to 24 V DC ±10 %
45 mA max.
2 V max.
0.2 mA max.
Input voltage
ON current *1
ON voltage *1
OFF current *2
OFF voltage *2
ON delay
OFF delay
Internal circuit
12 to 24 V DC ±10 %
5 mA min.
8.8 V min.
0.5 mA max.
0.8 V max.
0.1 ms max.
0.1 ms max.
Output voltage
Load current
ON residual voltage
OFF leakage current
Internal circuit
12 to 24 V DC ±10 %
45 mA max.
2 V max.
0.2 mA max.
•
Internal Specifications
[Input] signals: RESET, DI0 to DI7, DSA
PNP I/O type FZ2-305/FZ2-355/FZ2-505/FZ2-555
Parallel Interface
BUSY, RUN, OR, GATE, ERROR,
DO0-15, READY
[Output] signals: When STGOUT0 and 1 are not used,
connect the COM IN terminal.
COM IN
Input terminal
COM OUT
Output terminal
Load
COM IN
Input terminal
㩷
COM OUT
Load
I/O Connector wiring is the same as NPN I/O type.