Precautions for Correct Use

Installation Site

Install the product in a place that meets the following conditions:
• Surrounding temperature of 0 to +50 °C
• No rapid changes in temperature (place where dew does not form)
• Relative humidity of between 35 to 85 %
• No presence of corrosive or flammable gases
• Place free of dust, salts and iron particles
• Place free of vibration and shock
• Place out of direct sunlight
• Place where it will not come into contact with water, oils or chemicals

Orientation of Product

To improve heat dissipation, install the product in the 
following orientation only.

Ambient Temperature

• Maintain a minimum clearance of 50 mm above and below the 

controller to improve air circulation. A minimum clearance of 
10 mm between other devices must also be maintained on the 
right and left sides of the product. However, if the adjacent 
devices do not generate heat, provide at least 50 mm of 
clearance from the top of the Controller. For the clearance at 
the bottom and sides, follow the mounting method.

• Do not install the product immediately above significant 

heat sources, such as heaters, transformers, or 
large-capacity resistors.

• Do not let the ambient temperature exceed 50 °C (122 °F).
• Provide a forced-air fan cooling or air conditioning if the 

ambient temperature is near 50 °C (122 °F) so that the 
ambient temperature never exceeds 50 °C (122 °F).

Noise Resistance

• Do not install the product in a cabinet containing 

high-voltage equipment.

• Do not install the product within 200 mm of power cables.

Component Installation and Handling

• OMRON Components

Use only the camera and cables designed specifically for the product. 
Failure to observe this may result in malfunction or damage of the product.

• Connecting/Disconnecting Camera and Cables

Always turn OFF the Controller’s power before connecting or disconnecting a camera 
or cable.

• Touching Signal Lines

To prevent damage from static electricity, use a wrist strap or another device for 
preventing electrostatic discharges when touching terminals or signal lines in 
connectors.

• Handling a USB Memory

To remove a USB memory, make sure that data is not being read or written to it. 

  The LED on the USB memory flashes while data is being read or written, so make sure that it is lit steadily before removing the 

memory.

• Turning OFF the Power

Do not turn OFF the power while a message is being displayed indicating that processing is being performed. Data in memory will 
be corrupted, and the product may not operate correctly the next time it is started.

• Using the RESET Signal

Do not use the RESET input immediately after power is turned ON. When using the RESET input to synchronize startup timing, 
wait at least 15 second after the Controller’s power supply is turned ON before turning ON the RESET signal.

Maintenance

Turn OFF the power and take safety precautions before conducting inspections. Electrical shock can result from attempting safety 
inspections with the power turned ON.
• Clean the lens with a lens-cleaning cloth or air brush.
• Lightly wipe off dirt with a soft cloth.
• Dirt on the CCD must be removed using an air brush.
• Do not use thinners or benzene.

Confirming Package Contents

Do not install in this orientation.

Do not install in this orientation.

• Controller
• Instruction Manual (this manual)
• Booklet (“Please Read First”)
• Mounting bracket (for panel)
• Touch  pen

Qty.: 1
Qty.: 1
Qty.: 1
Qty.: 6 

* Supplied with the LCD integrated type only.

Qty.: 1 

* Supplied with the LCD integrated type only 

(provided inside the controller).

Box type

LCD integrated type

To reserve ventilation path, 
the feet must be mounted 
to the side panel that is 
positioned at the base.

Summary of Contents for Xpectia FZ2-30

Page 1: ...Vision Sensor Cat No 1842097 4A Xpectia FZ2 30_ FZ2 35_ FZ2 50_ FZ2 55_ INSTRUCTION MANUAL ...

Page 2: ... the following The FZ Series Vision Sensor must be operated by personnel knowledgeable in electrical engineering To ensure correct use please read this manual thoroughly to deepen your understanding of the product Please keep this manual in a safe place so that it can be referred to whenever necessary 㧖 The meaning of _ in model is described below 0 NPN I O type 5 PNP I O type 1842097 4A OMRON Cor...

Page 3: ...S AND SHOULD NOT BE RELIED UPON AS A SAFETY COMPONENT OR PROTECTIVE DEVICE FOR SUCH PURPOSES Please refer to separate catalogs for OMRON s safety rated products OMRON shall not be responsible for conformity with any standards codes or regulations that apply to the combination of products in the customer s application or use of the product At the customer s request OMRON will provide applicable thi...

Page 4: ...immediately after the power is turned OFF Dispose of this product as industrial waste Regulations and Standards The Controller conforms to the following standards EC Directive 89 336 EEC EMC EN standard European Standard EN61326 UL Standard UL61010 1 The following alert symbols are used in this manual Meanings of Alert Symbols The following alert statements apply to the products in this manual Eac...

Page 5: ...t Connecting Disconnecting Camera and Cables Always turn OFF the Controller s power before connecting or disconnecting a camera or cable Touching Signal Lines To prevent damage from static electricity use a wrist strap or another device for preventing electrostatic discharges when touching terminals or signal lines in connectors Handling a USB Memory To remove a USB memory make sure that data is n...

Page 6: ...standard accessory Right side view Controller Controller Monitor cable Camera cable Elastic camera cable FZ VSB 2 m 5 m 10 m Right angle camera cable FZ VSL 2 m 5 m 10 m Recommended Model By OMRON Corporation S8VS 12024 Use the monitor to check images and display the condition setting menus The Controller performs the image processing specified by the user settings and outputs the measurement resu...

Page 7: ...thernet connector Ethernet connector Monitor connector analog RGB Monitor connector analog RGB Power ground terminal POWER LED USB connector USB connector RS 232C RS 422 connector RS 232C RS 422 connector I O connector control lines data lines I O connector control lines data lines The following items can be connected to USB ports Commercially available track ball and mouse USB memory Never insert...

Page 8: ...d Output terminal COM IN COM OUT Input voltage ON current 1 ON voltage 1 OFF current 2 OFF voltage 2 ON delay OFF delay Internal circuit 12 to 24 V DC 10 5 mA min 8 8 V min 0 5 mA max 1 1V max 5 ms max 0 7 ms max Input signals STEP 1 ON current ON voltage This refers to the current or voltage values needed to shift from the OFF ON state The ON voltage value is the potential difference between each...

Page 9: ...rence between each of the input terminals and COM IN Output signals Output voltage Load current ON residual voltage OFF leakage current Internal circuit 12 to 24 V DC 10 45 mA max 2 V max 0 2 mA max Input voltage ON current 1 ON voltage 1 OFF current 2 OFF voltage 2 ON delay OFF delay Internal circuit 12 to 24 V DC 10 5 mA min 8 8 V min 0 5 mA max 0 8 V max 0 1 ms max 0 1 ms max Output voltage Loa...

Page 10: ...Connection Method Wiring RS 232C RS 422 Controller Use a shielded cable The maximum cable length is 15 m Use a compatible connector Recommended items RS CS control cannot be used Align the connector with the socket and press it straight into place then fix it with the screws on both sides of the connector XM2A 0901 XM2S 0911 OMRON Corporation OMRON Corporation Signal name SD RD GND Pin No 2 3 9 Si...

Page 11: ... 25 39 4 M4 Depth 6 Top face Bottom face 1 0 Mounting 1 2 3 Mounting the controller to the optional desktop stand The controller can be placed on a desk by attaching the optional desktop stand FZ DS to the rear of the controller For details refer to the instruction manual of the desktop stand Mounting the controller to the optional VESA attachment unit VESA compatible mounting of the controller is...

Page 12: ...18 54 39 4 M4 Depth 6 4 M4 Depth 6 4 M4 Depth 6 83 308 260 246 296 130 110 7 6 68 33 163 5 28 4 12 8 10 20 120 120 4 M3 Depth 6 20 120 120 7 6 Unit mm Unit mm Controller External Dimensions LCD integrated type FZ2 300 FZ2 305 FZ2 500 FZ2 505 Box type FZ2 350 FZ2 355 FZ2 550 FZ2 555 4 ...

Page 13: ...eakage current Noise resistance Vibration resistance Shock resistance Ambient temperature range Ambient humidity range Ambient environment Ground Degree of protection Environmental conditions according to IEC61010 1 Case materials Weight Controller Specifications General specifications ...