The following signal words are used in this manual.  

Indicates a potentially hazardous situation which, if not avoided, will result in minor or moderate injury, or 
may result in serious injury or death. Additionally there may be significant property damage.  

Meanings of Signal Words  

Installation Environment 

• Do not use the product in areas where flammable or explosive gases are present. 
• Install the product so that air can flow freely through its cooling vents. 
• Do not install the product close to high-voltage devices and power devices in order to secure the safety of operation and maintenance. 
• Make sure to tighten all installation screws securely. 

Power Supply and Wiring 

• Make sure to use the product with the power supply voltage specified by this manual. 
• Use a power supply cable and crimp terminals of the specified size. Do not simply connect the twisted ends of the wires directly to 

the terminal block. 
- Applicable wire size: 1.31 to 2.63 mm

2

 - 

Crimp 

terminals 

- Terminal screw: M4 

• Keep the power supply wires as short as possible (Max. 10 m). 
• Use a DC power supply with safety measures against high-voltage spikes (safety extra low-voltage circuits on the secondary side). 
• Ground the product’s ground terminal to less than 100 

• Use a grounding point that is as close as possible and keep the ground wire as short as possible. 
• Wire the Controller to the ground with a separate ground wire. To avoid grounding problems, do not share the ground wire with any 

other devices or wire the ground to the building's steel framing. 

• Before turning on the power supply, confirm that the wiring is correct again. 

Other 

• Do not attempt to dismantle, repair, or modify the product. 
• Should you notice any abnormalities, immediately stop use, turn OFF the power supply, and contact your OMRON representative. 
• Do not touch fluorescent or halogen lights while the power is ON or immediately after the power is turned OFF. 
• Dispose of this product as industrial waste. 

Regulations and Standards 

The Controller conforms to the following standards. 
EC Directive 89/336/EEC (EMC) 
EN standard (European Standard) EN61326 
UL Standard UL61010-1 

The following alert symbols are used in this manual.  

Meanings of Alert Symbols  

The following alert statements apply to the products in this manual. Each alert statement also appears at the locations needed in 
this manual to attract your attention. 

Alert statements in this Manual  

Precautions for Safe Use  

WARNING 

Indicates general prohibitions for which there is no 
specific symbol.  

Indicates the possibility of explosion under specific 
conditions.  

This product is not designed or rated for ensuring safety of persons. 
Do not use it for such purposes. 

A lithium battery is built into the Controller and may occasionally combust, explode, or burn if not treated properly. Dispose of the Controller 
as industrial waste, and never disassemble, apply pressure that would deform, heat to 100°C or higher, or incinerate the Controller. 

Since this product emits a visible light that may have an adverse affect on the eyes, do not stare directly into the light emitted 
from the LED. If a specular object is used, take care not to allow reflected light enter your eyes. 

This product must be used according to the instruction manual. Failure to observe this may result in impairment of functions 
and performance of the product.  

WARNING 

CAUTION 

Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury 
or in property damage.  

Indicates the possibility of injury by high temperature under specific conditions.  

Do not open the cover. Doing so may result in electric shock from internally used high voltages. 

Indicates the possibility of electric shock under specific 
conditions.  

Danger of burns 
Do not touch the case while the LED is ON or just after power is turned OFF, since it remains extremely hot. 

8.5 mm max. 

8.5 mm max. 

Indicates the possibility of laser radiation.  

CAUTION 

Summary of Contents for Xpectia FZ2-30

Page 1: ...Vision Sensor Cat No 1842097 4A Xpectia FZ2 30_ FZ2 35_ FZ2 50_ FZ2 55_ INSTRUCTION MANUAL ...

Page 2: ... the following The FZ Series Vision Sensor must be operated by personnel knowledgeable in electrical engineering To ensure correct use please read this manual thoroughly to deepen your understanding of the product Please keep this manual in a safe place so that it can be referred to whenever necessary 㧖 The meaning of _ in model is described below 0 NPN I O type 5 PNP I O type 1842097 4A OMRON Cor...

Page 3: ...S AND SHOULD NOT BE RELIED UPON AS A SAFETY COMPONENT OR PROTECTIVE DEVICE FOR SUCH PURPOSES Please refer to separate catalogs for OMRON s safety rated products OMRON shall not be responsible for conformity with any standards codes or regulations that apply to the combination of products in the customer s application or use of the product At the customer s request OMRON will provide applicable thi...

Page 4: ...immediately after the power is turned OFF Dispose of this product as industrial waste Regulations and Standards The Controller conforms to the following standards EC Directive 89 336 EEC EMC EN standard European Standard EN61326 UL Standard UL61010 1 The following alert symbols are used in this manual Meanings of Alert Symbols The following alert statements apply to the products in this manual Eac...

Page 5: ...t Connecting Disconnecting Camera and Cables Always turn OFF the Controller s power before connecting or disconnecting a camera or cable Touching Signal Lines To prevent damage from static electricity use a wrist strap or another device for preventing electrostatic discharges when touching terminals or signal lines in connectors Handling a USB Memory To remove a USB memory make sure that data is n...

Page 6: ...standard accessory Right side view Controller Controller Monitor cable Camera cable Elastic camera cable FZ VSB 2 m 5 m 10 m Right angle camera cable FZ VSL 2 m 5 m 10 m Recommended Model By OMRON Corporation S8VS 12024 Use the monitor to check images and display the condition setting menus The Controller performs the image processing specified by the user settings and outputs the measurement resu...

Page 7: ...thernet connector Ethernet connector Monitor connector analog RGB Monitor connector analog RGB Power ground terminal POWER LED USB connector USB connector RS 232C RS 422 connector RS 232C RS 422 connector I O connector control lines data lines I O connector control lines data lines The following items can be connected to USB ports Commercially available track ball and mouse USB memory Never insert...

Page 8: ...d Output terminal COM IN COM OUT Input voltage ON current 1 ON voltage 1 OFF current 2 OFF voltage 2 ON delay OFF delay Internal circuit 12 to 24 V DC 10 5 mA min 8 8 V min 0 5 mA max 1 1V max 5 ms max 0 7 ms max Input signals STEP 1 ON current ON voltage This refers to the current or voltage values needed to shift from the OFF ON state The ON voltage value is the potential difference between each...

Page 9: ...rence between each of the input terminals and COM IN Output signals Output voltage Load current ON residual voltage OFF leakage current Internal circuit 12 to 24 V DC 10 45 mA max 2 V max 0 2 mA max Input voltage ON current 1 ON voltage 1 OFF current 2 OFF voltage 2 ON delay OFF delay Internal circuit 12 to 24 V DC 10 5 mA min 8 8 V min 0 5 mA max 0 8 V max 0 1 ms max 0 1 ms max Output voltage Loa...

Page 10: ...Connection Method Wiring RS 232C RS 422 Controller Use a shielded cable The maximum cable length is 15 m Use a compatible connector Recommended items RS CS control cannot be used Align the connector with the socket and press it straight into place then fix it with the screws on both sides of the connector XM2A 0901 XM2S 0911 OMRON Corporation OMRON Corporation Signal name SD RD GND Pin No 2 3 9 Si...

Page 11: ... 25 39 4 M4 Depth 6 Top face Bottom face 1 0 Mounting 1 2 3 Mounting the controller to the optional desktop stand The controller can be placed on a desk by attaching the optional desktop stand FZ DS to the rear of the controller For details refer to the instruction manual of the desktop stand Mounting the controller to the optional VESA attachment unit VESA compatible mounting of the controller is...

Page 12: ...18 54 39 4 M4 Depth 6 4 M4 Depth 6 4 M4 Depth 6 83 308 260 246 296 130 110 7 6 68 33 163 5 28 4 12 8 10 20 120 120 4 M3 Depth 6 20 120 120 7 6 Unit mm Unit mm Controller External Dimensions LCD integrated type FZ2 300 FZ2 305 FZ2 500 FZ2 505 Box type FZ2 350 FZ2 355 FZ2 550 FZ2 555 4 ...

Page 13: ...eakage current Noise resistance Vibration resistance Shock resistance Ambient temperature range Ambient humidity range Ambient environment Ground Degree of protection Environmental conditions according to IEC61010 1 Case materials Weight Controller Specifications General specifications ...