Long-life Two-circuit Limit Switch

 

WLM

@

F-103

Lim

it 

Switch

es

Engineering Data

Electrical Durability: cos

φ 

= 1

Lamp-equipped Models

The operating status of the Switch can be checked using a neon
lamp of LED indictor.

Circuit checks and troubleshooting errors are easy done.

The built-in switch’s terminal screws are used to connect the lamp
terminal (indicator cover). Since the connection spring (coil spring) is
used for this connection, it will not be necessary to connect to the
lamp terminal. When a ground terminal is provided however, lead
wire method must be used.

WL-LD has a built-in rectifier stack, so it will not be necessary to
change the polarity.

The indicator cover is molded from diecast aluminum and has out-
standing sealing properties. Furthermore, regardless of whether the
power is connected or not, the operating status is shown (operating
or not operating), and indicators can be switched from light-ON when
operating and light-ON when not operating, by simply rotating the
lamp holder by 180

°

.

The lamp-equipped models are ideal in locations using a conveyor
belt where items need to be checked, or locations that are difficult to
inspect for faults.

Indicator Lamp and Load Operation

When the indicator lamp is set to light-ON when operating, connect
the load on the NC side, and set so that the load turns ON when the
actuator is free.

When the indicator lamp is set to light-ON when not operating, con-
nect the load on the NO side, and set so that the load turns ON when
the actuator is pushed down.

Light-ON when Operating

When the Switch’s contacts and the internal circuit of the lamp holder
are connected in parallel, there is large resistance from the internal
circuit, so the current will flow through the Switch’s contacts and the
load will turn ON.

When the contacts and the internal circuit are separated, only a
small voltage, enough to light the indicator lamp will flow to the lamp,
but the load will not turn ON.

Operation

Note: 1.

Light-ON when operating means that the lamp lights when
the Limit Switch contacts (NC) release, or when the actuator
rotates or is pushed down.

2.

Light-ON when not operating means the lamp remains lit
when the actuator is free, or when the Limit Switch contacts
(NO) close when the actuator rotates or is pushed down.

Operating temperature:  5

°

C to 30

°

Operating humidity:        40% to 70%

Switching current (mA)

Dur

ability (x 10

4

 oper

ations)

125 VAC

250 VAC

480 VAC

Operating frequency: 30 operations/min 
cos

φ

 = 1

Operation 
indicator 
window

Light emitting diode (LED)

Lamp holder

Contact spring

LIght-ON 
when 
operating 
(See note 1.)

Light-ON 
when not 
operating 
(See note 2.)

Light-ON when Operating

Light-ON when Not Operating

LED at bottom

LED at top

WL-LD

Power supply

Built-in switch

Load

Internal circuit

WL-LD

Power supply

Built-in switch

Load

Internal circuit

Summary of Contents for WLM -

Page 1: ...ibility when setting stroke zones Model Number Structure Model Number Legend 1 Actuators CA2 Roller lever Standard GCA2 Roller lever High precision H2 Roller lever Overtravel general purpose G2 Roller lever Overtravel high sensitivity 2 Wiring Specifications Blank Screw terminal G1 2 conduit K13A Direct wired connector 2 core AC K13 Direct wired connector 2 core DC K43A Direct wired connector 4 co...

Page 2: ...possible Head can be mounted in any of the four directions See note 3 One side operation possible Head can be mounted in any of the four directions See note 3 Screw terminal WLMCA2 LD WLMH2 LD WLMG2 LD WLMGCA2 LD Direct wired connector 2 core AC WLMCA2 LDK13A WLMH2 LDK13A WLMG2 LDK13A WLMGCA2 LDK13A DC WLMCA2 LDK13 WLMH2 LDK13 WLMG2 LDK13 WLMGCA2 LDK13 4 core AC WLMCA2 LDK43A WLMH2 LDK43A WLMG2 LD...

Page 3: ...ty 115 VAC 5 115 VDC 0 4 Inrush current NC 30 A max 15 A max See note NO 20 A max 10 A max See note Model Rated voltage Non inductive load Inductive load Resistive load Lamp load Inductive load Motor load NC NO NC NO NC NO NC NO DC 12 VDC 3 3 3 3 3 3 3 3 24 VDC 3 3 3 3 3 3 3 3 48 VDC 3 3 3 3 3 3 3 3 115 VDC 0 8 0 8 0 2 0 2 0 8 0 8 0 2 0 2 AC 115 VAC 3 3 3 1 5 3 3 3 2 5 Degree of protection IP67 Du...

Page 4: ...d down Operating characteristics WLMCA2 LD Standard models WLMH2 LD Overtravel models general purpose WLMG2 LD Overtravel models high sensitivity WLMGCA2 LD High precision models OF max 9 81 N 9 81 N 9 81 N 13 34 N RF min 0 98 N 0 98 N 0 98 N 1 47 N PT OT min 30 55 65 40 MD max 12 12 7 3 15 5 15 5 10 2 1 5 2 0 Lamp equipped Light ON when not operating Internal circuit Built in switch Lamp equipped...

Page 5: ... that the load turns ON when the actuator is free When the indicator lamp is set to light ON when not operating con nect the load on the NO side and set so that the load turns ON when the actuator is pushed down Light ON when Operating When the Switch s contacts and the internal circuit of the lamp holder are connected in parallel there is large resistance from the internal circuit so the current ...

Page 6: ...h with SPST NO NC contact form Bearing The bearing smooths the plunger movement Shaft Section Seal By fitting a double seal consisting of an oil seal and an X ring to the rotary shaft even greater sealing properties are achieved Head The Head can be mounted in any of the four directions by removing the screws at the four corners of the Head Requires maintenance excessive overtravel Proper range Re...

Page 7: ... 12 Allen head bolt Rubber cap Three M4 13 Lamp cover JIS B0202 G1 2 Effective thread 4 threads min Four M6 Depth 15 min 60 max Four 5 2 0 2 dia holes 0 17 5 dia 5 See note Four M3 5 length 26 5 M5 12 Allen head bolt Rubber cap Three M4 13 Lamp cover JIS B0202 G1 2 Effective thread 4 threads min 0 Four 5 2 0 2 dia holes Four M6 Depth 15 min 60 max 42 max SC 2FD M12 1 Note Stainless steel roller No...

Page 8: ...re to change the plunger for internal opera tions at the same time The operational plunger does not need to be changed on overtravel general purpose and overtravel high sensitivity models Roller Levers WLMCA2 WLMH2 WLMG2 WLMGCA2 Changing the operating direction By removing the Head on models which can operate on one side and then changing the direction of the operation al plunger one of three oper...

Page 9: ... changes in shape and quality This is due to deterioration including expansion and contraction and may result in reduced performance ineffective return and ineffective sealing leading to ineffective contact insulation leakage current and fire Confirm the possible effects of the operating environment on the Switch before use Built in Switch Do not replace the built in switch If the position of the ...

Page 10: ...n the shaft section can be seen Terminal Plate By using a short circuit plate as shown in the following diagram the Switch can be fabricated into a single polarity double break model When ordering specify WL Terminal Plate IWPA01 D dia dz dia dz dia 4 3 D dia 4 5 B 8 5 L 21 0 F 7 8 l 9 0 mm Ground terminal NO terminal NC terminal 16 0 15 9 0 2 2 1R 2R 3R t 0 6 Copper plate In the interest of produ...

Reviews: