Long-life Two-circuit Limit Switch
WLM
@
F-101
Lim
it
Switch
es
Specifications
■
Ratings
General-purpose Ratings
Refer to these ratings before using the product.
Screw Terminal Models
Note:
Only for high-sensitivity overtravel models.
Direct-wired/Pre-wired Models
Note: 1.
The above figures are for standard currents.
2.
Inductive loads have a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC).
3.
Lamp load has an inrush current of 10 times the steady-state current.
4.
Motor load has an inrush current of 6 times the steady-state current.
■
Characteristics
Note: 1.
The figures in parentheses for dielectric strength, are those for overtravel (high-sensitivity) or connector models.
2.
The values are calculated at an operating temperature of 5
°
C to 35
°
C, and an operating humidity of 40% to 70%. Contact your OMRON
sales representative for more detailed information on other operating environments.
Model
Rated
voltage
Non-inductive load
Inductive load
Resistive load
Lamp load
Inductive load
Motor load
NC
NO
NC
NO
NC
NO
NC
NO
Standard, overtravel
(except high-sensitivity),
and high-precision
115 VAC
10
3
1.5
10
5
2.5
12 VDC
10
6
3
10
6
24 VDC
6
4
3
6
4
48 VDC
3
2
1.5
3
2
115 VDC
0.8
0.2
0.2
0.8
0.2
Overtravel
(High-sensitivity)
115 VAC
5
---
---
---
115 VDC
0.4
---
---
---
Inrush current
NC
30 A max. (15 A max. (See note))
NO
20 A max. (10 A max. (See note))
Model
Rated
voltage
Non-inductive load
Inductive load
Resistive load
Lamp load
Inductive load
Motor load
NC
NO
NC
NO
NC
NO
NC
NO
DC
12 VDC
3
3
3
3
3
3
3
3
24 VDC
3
3
3
3
3
3
3
3
48 VDC
3
3
3
3
3
3
3
3
115 VDC
0.8
0.8
0.2
0.2
0.8
0.8
0.2
0.2
AC
115 VAC
3
3
3
1.5
3
3
3
2.5
Degree of protection
IP67
Durability (See note 2.)
Mechanical: 30,000,000 operations min. (10 mA at 24 VDC, resistive load)
Electrical:
750,000 operations min. (10 A at 115 VAC, resistive load),
but for high-precision models: 500,000 operations min. (10 A at 115 VAC, resistive load)
Operating speed
1 mm to 1 m/s (for WLMCA2)
Operating frequency
Mechanical: 120 operations/minute
Electrical:
30 operations/minute
Rated frequency
50/60 Hz
Insulation resistance
100 M
Ω
min. (at 500 VDC)
Contact resistance
25 m
Ω
max. (initial value)
Dielectric strength
1,000 VAC, 50/60 Hz for 1 min between non-continuous terminals. (Except connector models.)
2,200 VAC (1,500 V), 50/60 Hz for 1 min between non-current-carrying metal part and ground.
2,200 VAC (1,500 V), 50/60 Hz for 1 min between each terminal and non-current-carrying metal part.
Vibration resistance
10 to 55 Hz, 1.5-mm double amplitude
Shock resistance
Destruction: 1,000 m/s
2
min.
Malfunction: 300 m/s
2
min.
Ambient temperature
Operating: –10
°
C to 80
°
C (with no icing)
Ambient humidity
Operating: 95% max.
Weight
Approx. 275 g (for WLMCA2)