4-17
Chapter 4. Advanced Setup
4
Advanced
Setup
• Set CL-1's SSID as the same one as that of an access point to communicate. (In this
example those of AP-1 and AP-2)
• When performance of smart roaming switching time is required, combine WE70-AP and WE70-CL.
• For mobile operation of CL-1, make sure that CL-1 should not go into an area where radio
wave cannot reach from neither AP1 and AP-2.
• When smart roaming is being valid, and if CL-1's received electric field strength levels
from AP-1 and AP-2 are not very much different, roaming may not be available or may
take a long time.
• Repeating is available for 6 segments.
• As larger number of segments decreases throughput, take precautions for an application
that requires high speed. Always perform testing before actual operation.
(6) Check if communication is available between PC and PLC.Test the
roaming in the opposite direction and verify that access points should be
switched from AP-2 to AP-1 and that communication should be available
between PC and PLC.
Click
If the client has different SSID and/or encryp-
tion setup from the access point, "Communi-
cation Unavailable" is displayed.
CL-1
CL-1
(5) From CL-1 Setup screen "Information" menu, "Wireless Information",
"BSSID", verify that BSSID should be AP-2 value.
Caution
Step 3. Checking PC-PLC Communication
Execute the Ping command to PLC from PC connected to AP-1 and verify its response.
(1) Execute a ping command from your PC at command prompt.
Example:Ping 192.168.0.10 (Partner's IP address)
C:¥>ping 192.168.0.10
Pinging 192.168.0.10 with 32 bytes of data:
Reply from 192.168.0.10: bytes=32 time<1ms TTL=250
* If no response is returned, follow the steps below:
• Execute "arp -d" command.
• Verify if security settings are the same.
Summary of Contents for WE70-AP
Page 1: ...OPERATION MANUAL WE70 AP CL pan FA Wireless LAN Unit Cat No N153 E1 01...
Page 2: ......
Page 32: ...Chapter 1 Overview 1 12 1 Overview...
Page 98: ...Chapter 4 Advanced Setup 4 30 4 Advanced Setup...
Page 146: ......