Command and Response Frame Structures
Section 5-2
5-7
5-2-4 Response Command List
Response codes in response frames are shown below.
Type
Response
Code
Name
Description
“00”
Normal completion
The received command ends normally with no error.
Multi-processing end
Communications end response when a multi-trigger function is used.
“72”
Selective detection completion Communications end response when a selective access/detection func-
tion is used.
“74”
Polling command received
Polling command has been received normally.
Polling Check is received before the completion of communications with
a Tag.
Polling processing canceled
Polling processing is canceled before the completion of communications
with an ID Tag.
“75”
Data normal
Results of the memory calculation command (MK) check code verifica-
tion are normal.
Polling processing canceled
Polling processing is canceled after the start of communications with an
ID Tag.
Normal
completion
“76”
Data error
Results of the memory calculation command (MK) check code verifica-
tion show an error.
“10”
Parity error
A parity error occurs in one of the characters of the received command.
“11”
Framing error
A framing error occurs in one of the characters of the received com-
mand.
“12”
Overrun error
An overrun error occurs in one of the characters of the received com-
mand.
“13”
BCC error
The received command has an incorrect BCC.
“14”
Format error
The command format is incorrect.
A stop command is received in command-waiting status.
In Selective Access mode;
1) A temporary number not saved using the Tag detection command is
specified.
2) A tag detection command normal end is retried after it has been sent.
Host commu-
nications error
“18”
Frame length error
ETX is not received in 151 characters or less after STX is received.
“70”
Communications error
An error occurs during the communications with an ID Tag, and commu-
nications cannot end normally.
“71”
Write process error
Tag is in an area that can be read, but not written to.
You are trying to write to a locked page (i.e., write-protected).
The correct data cannot be written to the Tag.
Verify read results in an error.
“72”
No Tag error
No Tag is present in front of Antenna when a Trigger command is exe-
cuted.
There are multiple Tags within the communications area when using
Single Access mode.
Communica-
tions error
“79”
Command error
Refer to the correlation table of ISO/IEC Error Codes.
System error
“93”
Memory error
An error has occurred in the Reader/Writer memory.
“01”
Specified No. of Tags exceeded More Tags than have been specified in the Tag No. setting have entered
the communications area.
“02”
Specified No. of retries ex-
ceeded
Tag detection has been retried the specified number of times to find all
the Tags in the communications area, but some Tags have not been
detected.
“03”
No. of Tags exceeded
No. of retries exceeded
Two of the warning, “01” and “02,” have occurred.
“04”
Communications error
An error occurs during communicating with Tags, resulting in successful
communications with only some of the Tags.
“05”
Specified No. of Tags exceeded
Communications error
Two of the warnings, “01” and “04,” have occurred.
“06”
No. of Tags exceeded
Communications error
Two of the warnings, “02” and “04,” have occurred.
Warning
“07”
No. of Tags exceeded
No. of retries exceeded
Communications error
All the three warnings, “01,” “02,” and “04,” have occurred.
Note
The warning codes are used in a response code that is generated during the
multi-read process, in order to return read data in a Tag when a communica-
tions error occurs.