6-3
An example of setting to execute the following items is described.
Communication process
: Reads 16 bytes from the address 10h in a hexadecimal number in an automatic operation.
Judgment, OUT1 output
: 4 Bytes of data from the address 18 is "00000001" and turning ON for 0.5 seconds.
Judgment, OUT2 output
: ON at an error. (Time is not monitored.)
Judgment, RS-232C output : No output.
•
Sent command string
"SE00RDRAH1001010, = = 080400 XX, 0500, ER00 XX, 0000, XX + XX, 0000"
•
Description of sent command string
SE00RDRAH1001010
←
Execution command
Read 16 bytes from the address 10h.
==08040XX, 0500,
←
Specifies a condition of OUT1 output.
Output time (0.5 seconds).
No condition (B).
Condition (A) is judged as matched.
ER0XX, 0000,
←
Specifies a condition of OUT2 output.
ON (unlimited)
No condition (B).
Condition (A) is judged as unmatched. (All the error codes)
XX+XX, 0000
←
Specifies a condition of RS-232C output.
Fixed data.
No condition (B).
No condition (A).
6-3 Example of Setting