AutoImage Photometry Enabled
This bit is set to
1
when Auto Photometry is used.
This bit is set to
0
when AutoImage Photometry is complete.
・
AutoImage Photometry Complete
This bit is set to
1
when AutoImage Photometry processing is complete. If an error occurs, it is out-
put by Fault Code area.
・
Output 1 Status
Indicates the current state of the Parallel OUTPUT 1 signal.
・
Output 2 Status
Indicates the current state of the Parallel OUTPUT 2 signal.
・
Output 3 Status
Indicates the current state of the Parallel OUTPUT 3 signal.
・
Buffer Overflow
This bit is set to
1
when the read string length exceeds the size of the Decode Data area.
•
Fault Code
Outputs Error information when a code reader error occurs.
It can be set from the Command field of the Output Assembly.
Bit
State
0
Command Error Detected
1
Communication Error
2
Reserved
3
Host Port Buffer Overflow
4 - 31
Reserved
・
Command Error Detected
This bit is set to
1
when a Serial command fails to be executed.
・
Communication Error
This bit is set to
1
when a data error condition is detected in Serial (RS-232C) communication.
・
Host Port Buffer Overflow
This bit is set to
1
when a character string larger than the size set for the Decode Data area is re-
ceived.
•
Counters
Various counters of Read results after starting the device are output.
These counters can be set from the Command Field/Area of the Output Assembly.
Counters
Size (Bytes)
No Read
Read Cycle Counter
4
Mismatch per Read Cycle Counter
4
No Read
Counter
4
Trigger Counter
4
Matchcode
Counter
4
Mismatch Counter
4
・
No Read
Read Cycle Counter
Outputs the total number of Read Cycle No Reads.
・
Mismatch per Read Cycle Counter
Outputs the total number of Read Cycle Mismatches.
・
No Read
Counter
Appendices
A - 11
V430-F Series Autofocus Multicode Reader User Manual for Communication Settings
A-2 EtherNet/IP Detailed Specifications
A
A-2-1 Assembly Memory Allocation