Category
Command
Description
Response Data Example
(For Read string ABCDE.)
Device Con-
trol
<L1>
Parallel OUTPUT 1 Signal turns ON.
None
<L2>
Parallel OUTPUT 2 Signal turns ON.
None
<L3>
Parallel OUTPUT 3 Signal turns ON.
None
<l1>
Turn ON the target pattern (blue LED).
None
<l0>
Turn OFF the target pattern (blue LED).
None
<I>
Disables Read Cycle. While Read Cycle is
Disabled, it cannot accept a trigger.
None
<H>
Enables Read Cycle.
None
Counters and
Counter re-
sets
<q>
Gets the number of No Reads in the Read Cy-
cle. The Response data output is q/ followed
by a 9 digit value for the number of
No Read
<q/000000005>
<q0>
Clears the number of No Reads in the Read
Cycle.
None
<$>
Gets the Mismatch Count. The Response data
output is $/ followed by a 9 digit value for the
number of Mismatch.
<$/000000002>
<$0>
Clears the Mismatch Count.
None
<N>
Gets the number of No Reads. The Response
data output is N/ followed by a 9 digit value for
the number of No Reads
<N/000000005>
<O>
Clears the Mismatch Count.
None
<T>
Gets the Trigger Input Count. The Response
data output is T/ followed by a 9 digit value for
the number of Triggers.
<T/000000010>
<U>
Clears the Trigger Input Count.
None
<V>
Gets the Match Count when the
Matchcode
function is used. The Response data output is
V/ followed by a 9 digit value for the number
of
Matched strings.
<V/000000010>
<W>
Clears the Match Count.
None
<X>
Gets the Mismatch Count when the
Matchcode
function is used. The Response
data
output is X/ followed by a 9 digit value
for the
number of Mismatched strings.
<Y>
Clears the Mismatch Count.
None
3 Controlling Operation and Data Output with Ethernet
3 - 43
V430-F Series Autofocus Multicode Reader User Manual for Communication Settings
3-2 Controlling Operation and Data Output with Serial
(TCP)
3
3-2-6
Serial Command List