The following settings are set independent for each Output signal.
Change the Output signal number selection as needed for your application.
• WebLink -
Setup
-
Gear Icon
-
Advanced Settings
-
I/O
-
Trend Options (Output 1, 2, 3)
Setting Item
Setting Value
Description
Trend Analysis
Mode
•
Mismatch
•
No Read
•
Decodes per
Trigger
•
Mismatch:
Turns ON when the number of Mismatches for the most recent
Number of Triggers
cycle reaches the number set for
Number
to Output On
.
•
No Read
:
Turns ON when the number of No Reads for the most recent
Number of Triggers
cycle reaches the number set for
Number
to Output On
.
•
Decodes per Trigger:
Turns ON when the Number Of Decodes for the most recent
Number of Triggers
cycle reaches the number set for
Number
to Output On
.
Number of Triggers
0 to 255
The number of triggers in the Trend Analysis.
For example, if you set this to
25
, the Trend Analysis will be done
for the most recent 25 trigger inputs.
Number to Output
On
0 to 255
This is the threshold for turning on the Output signal Trend Analy-
sis is assigned to.
For example,
Trend Analysis Mode
:
No Read
,
Number of Triggers
:
25
,
Number to Output On
:
4
With these settings, the output signal turns ON when there are 4
No Read
in the last 25 triggers.
Decodes per Trigger
Threshold
0 to 65535
When the number of codes read within the Read Cycle falls below
the Decodes per Trigger threshold, the Output signal turns ON.
Setting Example
•
Read Cycle
Trigger
-
Mode
:
External Edge
End of Read Cycle
-
Mode
:
Timeout
Capture Mode
-
Captures Mode
:
Continuous
•
I/O
Decodes per Trigger Output
-
Decodes/Trigger Status
:
Enabled
Trend Analysis (Output 1)
-
Trend Analysis Mode
:
Decodes
per Trigger
Trend Analysis (Output 1)
-
Number of Triggers
:
1
Trend Analysis (Output 1)
-
Number to Output On
:
1
Trend Analysis (Output 1)
-
Decodes per Trigger
:
10
10 or more Reads in the Read Cycle : Signal OFF
9 or less Reads in the Read Cycle : Signal ON
Below is an Output assignment example and Timing chart.
[Example assignment of OUTPUT signals]
• Output 1: In Read Cycle
• Output 2: Trend Analysis
Output Mode: Pulse
2 Controlling Operation and Data Output with Parallel
2 - 14
V430-F Series Autofocus Multicode Reader User Manual for Communication Settings