Member Name
Size (Bytes)
DECODE CYCLE REPORT
16
DECODE
DATA
LENGTH
4
DECODE DATA
STRING
184
Total Size: 248 Bytes
Member Description
•
INFO BITS
Bit
State
Description
0
Run Mode
Is
1
when Read Cycle is enabled.
1
Connection Faulted
Always
0
while connected.
2 - 7
Reserved
‐
•
Configuration Change Detection
This bit is set to
1
if any configuration changes are made to the code reader after connecting.
If the setting is returned to the original state,
0
is set.
•
Device Status
Shows the current status of the code reader.
Bit
State
0
Run Mode
1
Trigger Acknowledged
2
Exposure Done
3
Decoding
4
Data Is Ready
5
Read Cycle Pass
6
Read Cycle Fail
7
General Fault
8
New
Matchcode
Acknowledged
9
Matchcode
Enabled
10
Image Sensor Calibrating
11
Image Sensor Calibration Complete
12
Training
13
Training Complete
14
Optimizing
15
Optimization Complete
16
AutoImage Photometry Enabled
17
AutoImage Photometry Complete
18
Output 1 Status
19
Output 2 Status
20
Output 3 Status
21
Buffer Overflow
22 - 30
Reserved
・
Run Mode
Shows Read Cycle Enabled/Disabled status.
0 = Read Cycle Disabled
c
annot accept Trigger. However, it can receive a command.
1 = Read Cycle Enabled State in which trigger can be accepted.
・
Trigger Acknowledged
Appendices
A - 9
V430-F Series Autofocus Multicode Reader User Manual for Communication Settings
A-2 EtherNet/IP Detailed Specifications
A
A-2-1 Assembly Memory Allocation