background image

3

Examples of signs

The 

 icon indicates caution (including warning and danger).

Matters involving actual caution are indicated by statements 
or pictures in or near 

.

Notes on Safety

 The warning signs and the sample icons shown here are listed for you to use this product safely and correctly as well as to 

prevent the risk of injury to you and others.

 The icons and meanings are as follows.

Warning sign

Contents

Indicates matters in which the possibility of death or severe bodily injury may arise as a result of 
incorrect handling.

Indicates matters in which bodily injury or material damage

*

 may arise as a result of incorrect 

handling.

The 

 icon indicates prohibitions (what you cannot do).

Matters involving specific prohibitions are indicated by text or 
pictures shown in or near 

.

The 

 icon indicates something that is compulsory (must be 

observed at any time).
Matters involving specific compulsory actions are indicated by 
statements or pictures shown in or near 

.

The pictured 
icon refers to 
“caution for 
flammability”.

The pictured 
icon refers to 
“prohibition to 
disassemble”.

The pictured 
icon refers 
to “general 
compulsion”.

The pictured 
icon refers to 
“caution for 
electric shock”.

The pictured 
icon refers 
to “general 
prohibition”.

The pictured 
icon refers to 
“unplugging the 
power plug”.

*

 Material damage refers to a wide range of damage involving your house, household goods, domestic animals, and pets.

 Only use medications as prescribed and instructed by your doctor.
 • Your physical conditions may change for the worse.

When you use the unit for the first time after purchasing it or after having not used it for a long time, be 
sure to clean and disinfect it. (Refer to Pages 15 to 17.)
 • Miscellaneous types of bacteria may propagate and you may get infected.

Clean and disinfect the medication cup, medication cup cover, mouthpiece and inhalation hose, each 
time the unit is used.
 • Miscellaneous bacteria may propagate and you may become infected. If the unit is going to be used 

by more than one person, prepare a disinfected medication cup, medication cup cover, mouthpiece 
and inhalation hose, for each person before using it. This will prevent cross-infection.

Be sure to immediately dry the cleaned and disinfected parts, then store them in a dry place in order to 
prevent them from getting contaminated in the future.

In case of any problem with your nebuliser please contact your local OMRON service representative
(address on/ inside package).

Do not use this device in combination with ventilation equipment.
 • The pressure in the ventilation system may reduce significantly.

When assembling the cleaned, disinfected, and dried parts, do not touch the places where the 
medication and the nebulised medication pass through directly with your hands to prevent possible 
infection.

Do not make any contact with the vibrator while the power plug is plugged into the electric outlet.
 • You may suffer electric shock or injure yourself.

Do not plug in or pull the power plug from the electric outlet with wet hands.
 • You may suffer electric shock or injure yourself.

Do not wash the main unit with water, or splash water to the power source, do not use the nebuliser 
while you are in bath or having a shower, never submerge the nebuliser in water.
 • Short circuit may occur in the unit or you may suffer electric shock.

Warning

Warning

Caution

NE-U17-E.indb   Sec1:3

NE-U17-E.indb   Sec1:3

14/12/2010   13:49:22

14/12/2010   13:49:22

Summary of Contents for Ultra Air NE-U17

Page 1: ...l professionals Only use medications as prescribed and instructed by your doctor Table of Contents Be sure to Read This Section Exemptions from Liabilities 1 Intended Use 2 Notes on Safety 3 About the...

Page 2: ...including the power source and installation environment 6 Trouble and or damage caused as a result of modifying and or improper repair of the product 7 Trouble and or damage caused by supreme forces s...

Page 3: ...who are unconscious or are not breathing spontaneously Environment This product is intended for use in a medical facility such as Hospital clinic and doctor s office Durable period Durable periods are...

Page 4: ...it for a long time be sure to clean and disinfect it Refer to Pages 15 to 17 Miscellaneous types of bacteria may propagate and you may get infected Clean and disinfect the medication cup medication cu...

Page 5: ...or damaged Do not fill the water tank with the liquid other than water tap water or distilled water The vibrator will deteriorate and may be damaged When parts are sterilised in an autoclave make sure...

Page 6: ...tank of the main unit Do not disinfect the unit by boiling in a microwave oven After cleaning and disinfecting the parts assemble them after they are completely dried Do not wipe the main unit with v...

Page 7: ...the Product 1 Easy to see large LCD displays air volume nebulisation rate set time remaining time and error location The back light illumination featured in the unit enables checking of the display i...

Page 8: ...IMER MIN WATER LEVEL MEDICATION CUP COVER FAN COVER TIMER POWER CONTINUOUS CONTINUOUS 1 2 3 START STOP Display of air volume The air volume is displayed in 11 levels Display of nebulisation rate The n...

Page 9: ...tion of the shortage of water Fan installation axis Fan Top of the main unit Back of the main unit START STOP Button Power cord Power Button Display of air volume Refer to the Description of the LCD D...

Page 10: ...If the water level in the water tank is lower than the water level mark a lower water level in water tank error will be displayed If the water temperature in the water tank is low the nebulisation rat...

Page 11: ...piece set 3 Turn on the Power Button After all items on the LCD display illuminate check that the ERROR display does not flash If the ERROR display flashes check the place where the error number is in...

Page 12: ...lation hose For inhalation using the accessories such as mouthpiece adjust the air volume and the nebulisation rate according to your preferences and the accessories being used The air volume 11 level...

Page 13: ...s the completion of time set by the timer and the unit stops operation When the operation ends 0 on the display illuminates and the display changes to the initial set time To terminate inhalation whil...

Page 14: ...the tube is not bent If the tube is bent the medication cannot be supplied If the tube is too long cut it to a proper length Attach the inhalation hose Set the timer to Continuous Turn the air volume...

Page 15: ...uct cover from the main unit Remove the bacterial filter cap of the long time nebulisation set Attach a bacterial filter to the long time nebulisation set Attach a connector to the bacterial filter At...

Page 16: ...the inside of the water tank by using alcohol Clean disinfect and immediately dry the medication cup cover medication cup holder medication cup inhalation hose mouthpiece set For the disinfection meth...

Page 17: ...t up after removing the nebulisation unit from the main device The dirty fan cover can be washed with water or detergent In order to install the fan position the fan to the fan installation axis secur...

Page 18: ...nnot be disinfected by boiling Typical disinfectants that can be used Disinfecting ethanol Glutaraldehyde Sterihyde 0 5 and other equivalent products Sodium hypochlorite Milton 0 1 Purax 0 1 and other...

Page 19: ...ilization by autoclave Refer to the Instruction Manual and the Notes on Handling of the sterilizer How to store the unit Store the parts after thoroughly drying them When storing the parts be careful...

Page 20: ...ug the power plug in the electric outlet correctly Refer to Page 10 Fill the water up to the specified water level mark in the operating chamber Refer to Page 9 Set the medication cup correctly Refer...

Page 21: ...Undersize Independently measured at SolAero Ltd Canada Dr John Dennis according to EN13544 1 2007 Measured by OMRON HEALTHCARE Co Ltd Notes Subject to technical modification without prior notice This...

Page 22: ...he unit and create a potentially unsafe situation Recommendation is to keep a minimum distance of 7 m Verify correct operation of the device in case the distance is shorter Further documentation in ac...

Page 23: ...hed with the fixing rubber string Enables the simultaneous inhalation by mouth and nose Material SEBS Packaging unit 3 sets Inhalation mask S set 4997207 0 Attached with the fixing rubber string Exclu...

Page 24: ...SUSAKA Co Ltd 1855 370 Kubo cho Matsusaka city Mie prefecture 515 8503 Japan Subsidiary OMRON HEALTHCARE UK LIMITED Opal Drive Fox Milne Milton Keynes MK15 0DG U K OMRON MEDIZINTECHNIK HANDELSGESELLSC...

Reviews: