background image

22

List of Optional Parts

–  Materials are indicated by 

abbreviations.

ABS : 

Acrylonitrile-butadiene-ethylene 
resin

EVA  : Ethylene vinyl acetic acid resin

PMP : 

Polymethyle pentane

PP : 

Polypropylene 

resin

PS : 

Polyethylene 

resin

SEBS : Styrene elastomer

Medication cup
(4997211-8)

Used to transmit the ultrasonic 
vibration.  (If it has any damage or 
deformation, the unit may not be able 
to nebulise.  Handle this part carefully.)
Material: PP
Packaging unit: 5 cups

Bacterial filter
(4997213-4)

Used for inhalation such as for 
tracheal lavage.
Materials: filter; PP, connector; PMP
Packaging unit: 1 1 adapter

Air filter set
(4997214-2)

Protects the unit from the dust in air.
Materials: case; PP, filter; PS
Packaging unit: 1 set

Air filter
(4997215-0)

Material: PS
Packaging unit: 5 filters

Nebulisation set
(4997216-9)

Used for normal nebulisation.
Materials: medication cup; PP, 
medication cup holder; ABS, 
medication cup cover; PMP, packing; 
silicone
Packaging unit: 1 set

Long time nebulisation set
(4997217-7)

Used for continuous nebulisation.  
To be used in combination with the 
supply medication set (4997206-1).
Materials: cover; PMP, cap; silicone
Packaging unit: 1 set

Mouthpiece set 
(4997212-6)

Used for inhalation by being held by 
the mouth.
Material: EVA
Packaging unit: 5 sets

Inhalation mask (L) set
(4997205-3)

Attached with the fixing rubber string.  
Enables the simultaneous inhalation 
by mouth and nose.
Material: SEBS
Packaging unit: 3 sets

Inhalation mask (S) set
(4997207-0)

Attached with the fixing rubber string.  
Exclusive for the inhalation by mouth.  
A size that can be used by an infant.
Material: SEBS
Packaging unit: 3 sets

Inhalation hose M (70 cm) with a 
cuff having the diameter of 20 mm
(4997209-6)

White hose guide tube (cuff) can be 
removed and installed.
Attach it to the hose by rotating 
clockwise.  Cut it to the proper length.
Material: SEBS
Packaging unit: 1 hose

Supply medication set
(4997206-1)

Supplies the meditation in order to keep 
the medication in the medication cup at 
a certain level.  Used for humidifying or 
inhalation for a long time.
Material: PP
Packaging unit: 1 set

Inhalation hose S (30 cm) with a 
cuff having the diameter of 20 mm 
(4997208-8)

White hose guide tube (cuff) can be 
removed and installed. 
Attach it to the hose by rotating 
clockwise. Cut it to the proper length. 
Material: SEBS
Packaging unit: 1 hose

Inhalation hose L (150 cm) with a 
cuff having the diameter of 20 mm
(4997210-0)

White hose guide tube (cuff) can be 
removed and installed.
Attach it to the hose by rotating 
clockwise.  Cut it to the proper length.
Material: SEBS
Packaging unit: 1 hose

Adapter
(4997218-5)
Material: PMP
Used for connecting 22 mm parts 
e.g. bacterial filter.

(20/22mm, ISO compatible)

Washer, 5 pcs
(4997285-1)

Materials: silicone

EN

NE-U17-E.indb   22

NE-U17-E.indb   22

14/12/2010   13:49:30

14/12/2010   13:49:30

Summary of Contents for Ultra Air NE-U17

Page 1: ...l professionals Only use medications as prescribed and instructed by your doctor Table of Contents Be sure to Read This Section Exemptions from Liabilities 1 Intended Use 2 Notes on Safety 3 About the...

Page 2: ...including the power source and installation environment 6 Trouble and or damage caused as a result of modifying and or improper repair of the product 7 Trouble and or damage caused by supreme forces s...

Page 3: ...who are unconscious or are not breathing spontaneously Environment This product is intended for use in a medical facility such as Hospital clinic and doctor s office Durable period Durable periods are...

Page 4: ...it for a long time be sure to clean and disinfect it Refer to Pages 15 to 17 Miscellaneous types of bacteria may propagate and you may get infected Clean and disinfect the medication cup medication cu...

Page 5: ...or damaged Do not fill the water tank with the liquid other than water tap water or distilled water The vibrator will deteriorate and may be damaged When parts are sterilised in an autoclave make sure...

Page 6: ...tank of the main unit Do not disinfect the unit by boiling in a microwave oven After cleaning and disinfecting the parts assemble them after they are completely dried Do not wipe the main unit with v...

Page 7: ...the Product 1 Easy to see large LCD displays air volume nebulisation rate set time remaining time and error location The back light illumination featured in the unit enables checking of the display i...

Page 8: ...IMER MIN WATER LEVEL MEDICATION CUP COVER FAN COVER TIMER POWER CONTINUOUS CONTINUOUS 1 2 3 START STOP Display of air volume The air volume is displayed in 11 levels Display of nebulisation rate The n...

Page 9: ...tion of the shortage of water Fan installation axis Fan Top of the main unit Back of the main unit START STOP Button Power cord Power Button Display of air volume Refer to the Description of the LCD D...

Page 10: ...If the water level in the water tank is lower than the water level mark a lower water level in water tank error will be displayed If the water temperature in the water tank is low the nebulisation rat...

Page 11: ...piece set 3 Turn on the Power Button After all items on the LCD display illuminate check that the ERROR display does not flash If the ERROR display flashes check the place where the error number is in...

Page 12: ...lation hose For inhalation using the accessories such as mouthpiece adjust the air volume and the nebulisation rate according to your preferences and the accessories being used The air volume 11 level...

Page 13: ...s the completion of time set by the timer and the unit stops operation When the operation ends 0 on the display illuminates and the display changes to the initial set time To terminate inhalation whil...

Page 14: ...the tube is not bent If the tube is bent the medication cannot be supplied If the tube is too long cut it to a proper length Attach the inhalation hose Set the timer to Continuous Turn the air volume...

Page 15: ...uct cover from the main unit Remove the bacterial filter cap of the long time nebulisation set Attach a bacterial filter to the long time nebulisation set Attach a connector to the bacterial filter At...

Page 16: ...the inside of the water tank by using alcohol Clean disinfect and immediately dry the medication cup cover medication cup holder medication cup inhalation hose mouthpiece set For the disinfection meth...

Page 17: ...t up after removing the nebulisation unit from the main device The dirty fan cover can be washed with water or detergent In order to install the fan position the fan to the fan installation axis secur...

Page 18: ...nnot be disinfected by boiling Typical disinfectants that can be used Disinfecting ethanol Glutaraldehyde Sterihyde 0 5 and other equivalent products Sodium hypochlorite Milton 0 1 Purax 0 1 and other...

Page 19: ...ilization by autoclave Refer to the Instruction Manual and the Notes on Handling of the sterilizer How to store the unit Store the parts after thoroughly drying them When storing the parts be careful...

Page 20: ...ug the power plug in the electric outlet correctly Refer to Page 10 Fill the water up to the specified water level mark in the operating chamber Refer to Page 9 Set the medication cup correctly Refer...

Page 21: ...Undersize Independently measured at SolAero Ltd Canada Dr John Dennis according to EN13544 1 2007 Measured by OMRON HEALTHCARE Co Ltd Notes Subject to technical modification without prior notice This...

Page 22: ...he unit and create a potentially unsafe situation Recommendation is to keep a minimum distance of 7 m Verify correct operation of the device in case the distance is shorter Further documentation in ac...

Page 23: ...hed with the fixing rubber string Enables the simultaneous inhalation by mouth and nose Material SEBS Packaging unit 3 sets Inhalation mask S set 4997207 0 Attached with the fixing rubber string Exclu...

Page 24: ...SUSAKA Co Ltd 1855 370 Kubo cho Matsusaka city Mie prefecture 515 8503 Japan Subsidiary OMRON HEALTHCARE UK LIMITED Opal Drive Fox Milne Milton Keynes MK15 0DG U K OMRON MEDIZINTECHNIK HANDELSGESELLSC...

Reviews: