Appendix B
Specifications
58
CPU Specifications
Programming Method
Ladder diagram
Instruction Length
1 address/instruction, (1 to 4 words/instruction)
Number of Instructions
71 (12 basic instru 59 special instructions)
Execution Time
3 to 8
µ
s (basic instructions)/22 to 504
µ
s (special instructions)
Memory Capacity
24K words
I/O bits
512 (0000 through 3115)
IR bits
416 (3200 through 5715)
SR bits
88 (5800 through 6307)
TR bits
8 (0 through 7)
HR bits
512 (0000 through 3115)
LR bits
512 (0000 through 3115) PC Link: max. configuration 8 PCs
Timers/Counters
128 (TIM/CNT 000 through 127)
TIMs: 0 through 999.9 s
TIMHs: 0 through 99.99 s
CNT: 0 through 9999 counts
DM words
512 (0000 through 511) 16 bits/word
Control Input Signal
START INPUT (in RUN mode, PC operates when contacts are closed and stops when
contacts are opened)
Input Voltage: 24 mA 24 VDC
Control Output Signal
RUN INPUT (Contacts are closed while PC is in RUN mode)
Max. switching capacity:
2 A 250 VAC (resistive load)
0.5 A 250 VAC (inductive load, cos of phase angle= 0.4)
2 A 24 VDC
Memory Protection
Status of HR bits, preset value of counters (CNT), and contents of data memory (DM) are
retained during power failure. Length of memory protection depends on the Memory Pack
model being used (refer to
Battery Life
4 years at 25
°
C, battery life is shortened at temperatures higher than 25
°
C. Replace battery
with new one within 1 week when ALARM indicator blinks.
Self-diagnostic Functions
CPU failure (watchdog timer)
Battery failure
Cycle time error
Memory failure
I/O bus failure, etc.
Program Check
Program check (executed on start of RUN operation):
END missing
JMP-JME error
Coil duplication
Circuit error
DIFU/DIFD over error
IL/ILC error
(Program can be checked by Programming Console or GPC.)
Summary of Contents for SYSMAC C500
Page 1: ...Cat No W132 E1 4 Programmable Controller SYSMAC C500...
Page 2: ...C500 Programmable Controller Installation Guide Revised May 2000...
Page 37: ...29 SECTION 4 System Connections 4 1 Current Consumption 30 4 2 I O Connections 33...
Page 49: ...43 SECTION 6 Power Considerations...
Page 54: ...49 SECTION 7 Safety Considerations...
Page 58: ...53 A Inspection and Maintenance 54 B Specifications 57 C Standard Models 97 Appendix...
Page 96: ...Appendix B Specifications 91 A shape I O Unit B shape I O Unit...
Page 97: ...Specifications Appendix B 92 C shape I O Unit D shape I O Unit...