N A V I G A T I N G T H E S C R E E N S
1 2
18
H-T40
M
-P Manual Rev.A
Note: The status display cannot be used to initiate any kind of machine
safety stop since the communication between the G9SP and status
display touchscreen is not control reliable. The Reset function,
however, is not used to stop the machine. The machine is already in a
safe state before the reset command is initiated. If power loss or
communication failure were to occur, the machine would remain in a
safe state. Because there is a chance of this, a redundant manual reset
switch is recommended.
Figure 12-8 G9SP Configurator
Figure 12-9 Zone Reset Screen
G9SP Optional Input Communication Bit
Zone Status
[bit00]: Optional Communication Reception Data
Reset Zone 1
[bit01]: Optional Communication Reception Data
Reset Zone 2
[bit02]: Optional Communication Reception Data
Reset Zone 3
[bit03]: Optional Communication Reception Data
Reset Zone 4
Table 12-1 Optional Input Communication Bit