OMRON STI
©
99885-0010 Rev.A
Figure 12-2 Output Tag List
G9SP Optional Output Communication Bit
Zone Status
[bit00]: Optional Communication Transmission Data
Zone 1
[bit01]: Optional Communication Transmission Data
Zone 2
[bit02]: Optional Communication Transmission Data
Zone 3
[bit03]: Optional Communication Transmission Data
Zone 4
Table 12-1 G9SP Optional Output Transmission Data
Figure 12-3 G9SP Configuration Example
12.2. S
AFETY
I
NPUT
S
TATUS
This screen page will display the current state of the G9SP safety
inputs. A dark box represents a closed condition (power is going to the
input) i.e., light curtain is unblocked, e-stop is not pressed, safety door
interlock is closed. A light grey box represents an open signal (power
removed from signal) i.e. light curtain blocked, e-stop pressed, door
open.