No.14S056-11
43
STC-CMC120APCL, STC-CMB120APCL
Specifications and Users guide
Command No.
Command Descriptions
78H:
TESTP[7..0]
[Test Pattern] Initial data: TESTP [7..0] = 00H
Sets the test pattern video output.
D[7..0]
D7
D6
D5
D4
D3
D2
D1
D0
D7 to D5:
0: Normal Video Image
1: Gray Scale
2: Ramp
3: 100% White
4: White Clip
6: Color Bar(RGB BAYER)
Others: Black
79H:
EFFCT[7..0]
[Image effect selection] Initial data: EFFCT[7..0] = 00H
Sets the image effect.
Image data depends on Tap number of CameraLink output. If the value is not enough, drop off the value.
When horizontal start pixel position is larger than actual number, horizontal start pixel position should be set 0.
D[7..0]
D7
D6
D5
D4
D3
D2
D1
D0
D7:
Negative / Positive video selection
0: Positive image
1: Negative image
D6 to D0: Image effect
00H: No effect (Original)
01H: 9bit gradation
02H: 9bit gradation
03H: 7bit gradation
04H: 6bit gradation
05H: 5bit gradation
06H: 4bit gradation
07H: 3bit gradation
08H: 2bit gradation
09H: 1bit gradation
0A to 7FH: No Function
(Prohibited settings. Do not set these values)
80H:
E2P[7..0]
[EEPROM control] Initial data: E2P[7..0] = 0
D[7..0]
D7
D6
D5
D4
D3
D2
D1
D0
D7 to D1: No function
Always
set as “0000000”
D0:
Write control to the EEPROM
0: Prohibited
1: Accept
Note: This bit is cleared to “0” automatically by the internal processes after the execution of the command.
81H:
INI[7..0]
[Reload camera default setting] Initial data: INI [7..0] = 00H
Sets the factory setting.
D[7..0]
D7
D6
D5
D4
D3
D2
D1
D0
Note: Once reloaded the camera setting, this register may set “0” automatically. setting data does not save on
EEPROM through this register.
D[7..0]:
Factory Setting
0: No Function
170: Reload factory setting
For more information please contact Aegis Electronic Group, Inc. *(888)687-6877 *[email protected] *http://www.aegiselect.com