No.14S056-11
48
STC-CMC120APCL, STC-CMB120APCL
Specifications and Users guide
Command No.
Command Descriptions
DEH:
DEF_M[7..0]
[
Pixel defect correction mode1
] Initial data: DEF_M [7..0] = 1
Sets the pixel defect correction. As for the x-y coordinate of defect pixel, please refer to the
D[7..0]
D7
D6
D5
D4
D3
D2
D1
D0
D7 to D4:
D3 to D2:
Upper Address
No Function
0 to 9
Always set as “
00”
D1:
Highlight the corrected pixel
0: Disable
1: Enable
D0:
Pixel Defect Correction
0: Disable
1: Enable
When Highlight the corrected pixel is Enable, corrected pixel appeared with highlight.
※
D7 toD4 is Device Code : to set the X-Y coordinate of defect pixel with 3AH.
DFH:
DEF_M2[7..0]
[
Pixel defect correction mode
2] Initial data : DEF_M2[7..0] = 70H
Sets the artificial effect with pixel defect correction.
D[7..0]
D7
D6
D5
D4
D3
D2
D1
D0
D7:
No Function
Always set as “
0”
D6:
AOI
0: Disable
1: Enable
D5:
D4:
Vertical Flip
Horizontal Flip
0: Disable
0: Disable
1: Enable
1: Enable
D3 to D0: No Function
Always set as “
0000”
※
As for the x-y coordinate of defect pixel, please refer to the
Device Code:3AH
E3H:
FPN[7..0]
[
FPN Correction Mode
] Initial data: FPN[7..0] = 1
Sets the FPN Correction (
※
FPN
:
Fixed Pattern Noise)
D[7..0]
D7
D6
D5
D4
D3
D2
D1
D0
D7 to D1: No Function
Always set as “
0000000”
D0:
FPN Correction Mode
0: Disable
1: Enable
EEH:
MOD6[7..0]
EFH
MOD6[15..8]
[
The camera function mode
] Initial data: MOD6 [7..0] = 0
Sets the camera TAP number for each setting
D15 to D0:
TAP Number
0: 2 TAP
1: 4 TAP
2: 8 TAP
3: 10 TAP
4-15: No function
16: 3 TAP
More than 17: No function
For more information please contact Aegis Electronic Group, Inc. *(888)687-6877 *[email protected] *http://www.aegiselect.com
Aegis
Electronic
Group,
Inc.