Display window for new sensor settings New settings of E3NT-R
Section 8-5
8-5-1-2
I/O-Mode submenu tab
The general parameters of Outputs 1 and 2 are set in the
I/O-Mode
submenu.
8-5-1-2-1
Pin assignments
The functions of
Connector pin 2
and
Connector pin 5
are set in the
Pin
Assignment
box.
In total, the sensor can be operated with a maximum of three inputs/outputs,
and a maximum of two outputs is possible at the same time.
The functions of the inputs/outputs can be set in the following order:
Connector pin 4
is always defined as
Output 1 (OUT1)
and cannot be modi-
fied.
Connector pin 2
can be set as
test input (TEST)
or
alarm output
(ALARM)
.
Connector pin 5
can be set as the
test input (TEST
) or deactivated.
•
Test input TEST
The emitter is deactivated if a signal in the operating voltage range (at
least 10 V) is applied to this input.
If the sensor is in the light-on state, the receiver detects the absence of
the emitted light reflected by the measured object.
The output state changes.
Summary of Contents for SENSOR SUPPORT SOFTWARE S3
Page 1: ...OPERATION MANUAL Software Description SensorSupportSoftware S3 Cat No E31E EN 01 ...
Page 2: ......
Page 4: ...4 ...
Page 9: ...9 SECTION 2 Safety notes 2 1 Safety notes 10 ...
Page 11: ...11 SECTION 3 Program installation 3 1 Installation 12 3 2 Deinstallation 12 ...
Page 13: ...13 SECTION 4 Connecting the sensor to the PC 4 1 Connecting the sensor to the PC 14 ...
Page 15: ...15 SECTION 5 Program start 5 1 Starting the SensorSupportSoftware 16 ...
Page 19: ...Starting the SensorSupportSoftware Section 5 1 19 E3NT R ...
Page 20: ...20 Starting the SensorSupportSoftware Section 5 1 ...
Page 21: ...21 SECTION 6 Program definitions 6 1 Program control keys 22 ...