46
Display window for new sensor settings New settings of E3NT-L
Section 8-2
8-2-2-3-2
Output mode
The output circuit is set in the
Output mode
box. The output circuit can be set
jointly for both outputs:
•
PNP,
plus-switching, open collector
•
NPN,
minus-switching, open collector
•
Complementary,
push-pull, plus/minus-switching (factory default setting)
The sensor is set by default to the
push-pull output
(complementary). In this
output setting, both output transistors are alternately active.
When the output circuit is set to
PNP
or
NPN
, the relevant output circuit that is
currently not in use is switched off.
Both output circuits are resistant to short-circuits and are polarity-safe.
8-2-3
Basic settings tab
The general parameters of the selected sensor are set in the
Basic settings
menu.