6-3-3
Power OFF Using the Power ON/OFF Input
1
Ensure all programs are closed.
If required, close all active programs.
2
Supply a 24 VDC signal to the Power ON/OFF Input (pins 3 and 4) of the I/O connector.
The input signal must remain ON for a minimum of 60 ms and a maximum of 750 ms to be
correctly detected by the Industrial Panel PC.
The Industrial Panel PC will shutdown.
Note that this behaviour can be reconfigured with the Power Options settings.
3
Wait until the PWR LED is OFF.
The Panel PC is powered OFF.
Additional Information
• Refer to
4-2-2 I/O Connector Specifications
on page 4-21 for connector specifications.
• Refer to
on page 5-38 for wiring details.
6-3-4
Forced Power OFF Using the Power Button
Precautions for Safe Use
Press the power button for several seconds to force the product shutdown. Always back up files
in the planned way to prevent data loss or system file corruption.
1
Ensure all programs are closed.
If required, close all active programs to prevent losing unsaved data.
2
Press and hold the power button on the Panel PC for 5 to 10 seconds.
Refer to
on page 3-12 for power button location information.
The Industrial Panel PC will power OFF.
Any optional operating system settings related to power OFF will be disregarded.
3
Wait until the PWR LED is OFF.
The Panel PC is powered OFF.
Confirm normal operation and check all product settings because unsaved data was lost.
6 Operating Procedures
6-6
NY-series Industrial Panel PC Hardware User's Manual (W555)
Summary of Contents for NYP - 1 Series
Page 4: ...Introduction 2 NY series Industrial Panel PC Hardware User s Manual W555...
Page 10: ...Index CONTENTS 8 NY series Industrial Panel PC Hardware User s Manual W555...
Page 44: ...1 Overview 1 10 NY series Industrial Panel PC Hardware User s Manual W555...
Page 261: ...I Index I 1 NY series Industrial Panel PC Hardware User s Manual W555 I...
Page 264: ...Index I 4 NY series Industrial Panel PC Hardware User s Manual W555...
Page 265: ......